dataFEED EdgeGate

dataFEED EdgeGate : Connexion de vos PLCs Siemens et Modbus vers IoT Hubs

Passerelle pour connecter vos PLCs Siemens et Modbus vers un Cloud. Communication Bidirectionnel et hautement sécurisée vers la suite Microsoft Azure IoT

dataFEED edgeGate est la passerelle connectant les réseaux industriels vers des applications IT, fonctionnant “on premise” ou sur le Cloud.

La passerelle EdgeGate connecte vos PLCs with des applications OPC UA.  edgeGate connecte vos PLCs au Cloud, via le protocole MQTT. De plus la passerelle offre une intégration à de spécifique IoT Hubs Avec son standard OPC UA, la configuration est simple et la sécurité est optimale. La passerelle EdgeGate est facile et rapide à mettre en oeuvre avec de petites solutions et permets d’évoluer vers une charge plus importante.

Connection of IoT Hubs with Siemens and Modbus PLCs

  • Adjustable topic settings for MQTT payload
  • Perform analytics, monitoring, and create globally available dashboards in cloud solutions from different vendors, e.g. Amazon AWS, IBM Bluemix, Microsoft Azure
  • Integration of OPC UA and MQTT client applications running on-premise as well as in private and public clouds
  • Worldwide remote access to field data
  • Suited to new applications such as IoT or analytics
  • Use edgeGate for migration or retrofit upgrades
  • No PLC programming necessary
  • Symbol import from STEP 7 and TIA Portal projects
  • No software updates, operating system patches, or PC updates required

Integration with Microsoft Azure

  • Direct data access from Microsoft Azure to Siemens and Modbus PLCs
  • Bidirectional data exchange between cloud and shop floor by accessing OPC UA Servers on edgeGate or in OT network via integrated Microsoft OPC Proxy and Publisher components

Industry-proven Security

  • Physically separate interfaces and separate configuration rights for OT and IT networks preventing intrusions
  • Supporting security standards as SSL/TLS and X.509 certificates
  • OPC UA compliant data encryption and user authentification
Hardware Processor Altera Cyclone V SoC with Dual-core ARM Cortex-A9
Connectors 2 x IEEE 802.3 100BASE-TX/10BASE-T (independent interfaces)
Status LEDs PWR (power supply), RUN (running), ERR (error), SYS (configuration)
Dimensions (H x W x D) 100 mm x 22.5 mm x 105 mm
Power Supply 18 VDC … 32 VDC, SELV/PELV supply mandatory Typically 200 mA, maximum 1 A at switch-on
Operating Temperature, Horizontal DIN Rail Installation -40 °C .. 50 °C (0 mm minimum distance)
-40 °C .. 55 °C (22.5 mm minimum distance)
Operating Temperature, Vertical DIN Rail Installation -40 °C .. 35 °C (0 mm minimum distance)
-40 °C .. 40 °C (22.5 mm minimum distance)
Storage Temperature -40 °C .. 85 °C
Relative Humidity 10 % … 90 %, non-condensing
Weight About 0.2 kg
Mounting DIN Rail (35 mm)
Housing Phoenix Contact ME MAX
Protection Class IP20
Software IT Network / Cloud Connectivity OPC UA (Server, 60,000 items in total), MQTT (Publisher, up to 1,000 topics)
Controller Connectivity RFC1006, Modbus TCP
Maximum Number of Controllers 5
Supported IoT Hubs Microsoft Azure connected factory, Microsoft Azure IoT Hub, IBM Watson IoT Hub, General Electric Predix, Amazon AWS, etc.
Supported Controllers Siemens S7-300, S7-400, S7-1200, S7-1500
Modbus TCP-compatible controllers (Schneider Electric, Wago, Beckhoff, Phoenix Contact, etc.)
Supported Engineering Tools SIMATIC STEP 7, TIA Portal V13, V13 SP1, V14, V14 SP1
Conformity Emission EC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 55011, Group 1, Class A EC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 55022, Class A EC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 61000, Part 6-4 FCC CFR45, Part 15 Section 15.107 and 15.109 (Class A), VCCI Class A Information Technology Equipment 2002
Immunity EC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 61000, Part 6-2
GAA-YY-145122 edgeGate

Scope of Delivery

Hardware edgeGate
Software Tool for configuration over integrated web interface, dataFEED Exporter for easy symbol import from Siemens Project Files
Documentation Quick Startup Guide (printed documentation)

Consultez nous pour des formations sur ce produit

FG-260

FG-260 : Ethernet IP -> PROFINET Gateway

FG-260

FG-260 : EtherNet/IP to PROFINET Gateway with PROFINET Controller Functionality

The FG-260 implements a gateway between EtherNet/IP and PROFINET networks. It supports EtherNet/IP Adapter and PROFINET Controller functionality. The integration in PLC programs is provided via EtherNet/IP means, while the PROFINET communication is defined using a configuration tool (e.g. Communication Configuration Tool as included in scope of delivery). The runtime operation can be monitored and adjusted using a built-in web server.

Simple Integration Through Add-On Instructions

  • Data access of PLC program to PROFINET Devices without requiring detailed PROFINET knowledge
  • Mapping between the two protocols generated by provided tools
  • Usage of Add-On Instructions (AOI), containing detailed PROFINET data type definitions
  • Transparent communication overcoming protocol differences

Time Saving Configuration Creation and Verification

  • Configuration tool for online access to PROFINET Devices via the network
  • Easy assignment of device properties
  • Early identification of discrepancies between offline configuration and real situation

Built-In Web Server For Monitoring And Interaction

  • Status information about both protocols
  • Monitoring of mapping as well as of exchanged data
  • Individual modification of FG-260 settings, including address information
  • Download and upload of all FG-260 configuration information using web server

Different Use Cases are addressed

  • Direct access from Ethernet/IP Scanner in the PLC to PROFINET field devices
  • Access to machines with internal PROFINET network by deploying I-Device capabilities
Hardware
Processor Altera Cyclone V SoC with Dual-core ARM Cortex-A9
Status LEDs (Gateway) PWR (power supply), RUN (running), ERR (error), CFG (configuration upload)
Status LEDs (EtherNet/IP) Net (network), Mod (module)
Status LEDs (PROFINET) SF (system fault), BF (bus fault)
Connectors 2 x IEEE 802.3 100BASE-TX/10BASE-T (1 Ethernet port per protocol)
Dimensions (HxWxD) 100 mm x 35 mm x 105 mm
Weight ca 0.25 kg
Power Supply 18 VDC … 32 VDC, SELV/PELV supply mandatory
Typically 200 mA, maximum 1 A at switch-on
Operating Temperature, Horizontal DIN Rail Installation -40 °C … 55 °C (0 mm minimum distance)
-40 °C … 65 °C (17.5 mm minimum distance)
Operating Temperature, Vertical DIN Rail Installation -40 °C … 40 °C (0 mm minimum distance)
-40 °C … 50 °C (17.5 mm minimum distance)
Storage Temperature -40 °C … 85 °C
Relative Humidity 10 % … 90 %, non condensing
Cooling Convection, no fan
Mounting DIN Rail (35 mm)
Protection Class IP20
Software
Protocols EtherNet/IP Adapter (Up to 2 input and 2 output assemblies with up to 255 Bytes data each, minimum RPI: 8 ms)
PROFINET Controller (up to 8 devices at 1 ms cycle time)
Additional Functionality Mapping application, web server
Supported Versions of Rockwell Automation PLC Programming Software V16 – V21
Emission Conformity EC Directive 2004/108/EG “Electromagnetic Compatibility“, EN 55011, Group 1, Class A
EC Directive 2004/108/EG “Electromagnetic Compatibility“, EN 55022, Class A
EC Directive 2004/108/EG “Electromagnetic Compatibility“, EN 61000, Part 6-4
FCC CFR45, Part 15 Section 15.107 and 15.109 (Class A),
VCCI Class A Information Technology Equipment 2002
Immunity Conformity EC Directive 2004/108/EG “Electromagnetic Compatibility“, EN 61000, Part 6-2
Certifications CE
EN/IEC 61010-1 and CB
EN/IEC 61010-2-201 and CB
UL 61010-1 and UL 61010-2-201
GCL-CA-010260 FG-260

Scope of Delivery

Hardware Gateway FG-260
Software EDS File, Common Configuration Tool on CD-ROM, Search-and-Configure Tool
Documentation Quick Startup Guide as printed documentation, User Guide on CD-ROM

Training on demand

People interested in this product, might be interested in :

THLink Profinet

CAN-NMEA2000

Kit de démo CAN MARINE : NMEA2000 CAN Scope KIT

Kit de démo CAN MARINE : NMEA 2000 CAN Scope KIT

Construsisez et testez votre réseau CAN Marine NMEA 2000

Brochure

Le kit CAN Marine NMEA2000, intègre des outils professionels : CAN Analyser ( X-Analyser 3 ) et le tout nouveau hardware Picoscope, pour le marché Marine.

Ce kit contient:

  • Logiciel X-Analyser 3 Professional pour CAN/J1939/NMEA2000
  • L’interface CAN vers USB pour  X-Analyser.
  • PicoScope 2206B USB oscilloscope et sondes Scopes – livré avec le logiciel Picoscope ( logiciel oscilloscope)
  • Cable M12 vers D9 pour interfacer le X-Analyser au système  NMEA2000.
  • Cable M12 vers prise BNC dual, pour interfacer du Piscope vers le système NMEA2000
  • le tout dans un sac Warwick control
  • Clef USB avec les logiciels nécessaires

Le kit comprend :


Notes d’applications et nécessaire à la conception du réseaux
Interface USB
X-Analyser 3 Standard2
OBD (male) vers cables 2 x 9-pin DSUB
Simulateur OBD/ECU
Sac de transport

 Ref : ATV-NMEA2000 demo KIT

Formation sur CAN MARINE : NMEA2000 sur demande

Contenu de la formation