IES-3424DSFP-2P-PT

24 10/100TX + 4 Dual Speed SFP L2+ Industrial Managed Ethernet switch

  • Support PTPv2 two-step transparent clock @ 4 100/1000M ports
  • IEC 61850-3 & IEEE1613 compliance
  • Goose monitoring; Built-in MMS server for power SCADA
  • Enhanced G.8032 ring protection < 20ms for single ring. Supports auto mode, enhanced mode, train mode and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16 MSTI /RSTP
  • Miss-wiring avoidance & Repowered auto ring restore (node failure protection)
  • User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***; Complete CLI
  • Support LACP link aggregation, IGMP v3/router port, DHCP server & DHCP Option82 for Port/Vlan based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH/SSL, HTTPS, INGRESS/EGRESS ACL L2/L3, IPv6, SMS**
  • USB slot for edited restoration and auto backup

Lantech IES-3424DSFP-2P-PT is a high performance L2 + managed industrial IEC61850-3 Ethernet switch which provides L2 wire speed and advanced security function for network aggregation and backbone deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms including dynamic coupling ring, and enhanced mode for easy configuration, comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ* (double tag VLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.

The exclusive GOOSE monitoring function (IEC packet) can display the counter of GOOSE message transmitted and received by port. The built-in MMS (Manufacturing Messaging Specification) server can help power SCADA to monitor and control switch by data modeling.

The IES-3424DSFP-2P-PT also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IES-3424DSFP-2P-PT is able to alert with the LED indicator and disable ring automatically. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.

DHCP option 82 and relay agent function (Port/Vlan based DHCP distribution) can offer the same IP address on port base or vlan base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The built-in DHCP Option 82 server offers the convenience of policy setting on the switch. Mac based DHCP server function assigns an IP address according to its MAC address to include dumb switches in DHCP network.

The user friendly UI, innovative auto topology drawing and topology demo makes IES-3424DSFP-2P-PT much easier to get hands-on. The IES-3424DSFP-2P-PT supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.

Lantech IES-3424DSFP-2P-PT features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over Vlan for redundant links with 16 MSTI.

The configuration file of Lantech IES-3424DSFP-2P-PT can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead. The USB slot allows user to backup/ restore configuration.

QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.

The IES-3424DSFP-2P-PT DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IES-3424DSFP-2P-PT will immediately send an email & SMS** text message to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.

Lantech IES-3424DSFP-2P-PT supports dual power inputs from DC9.5~60V, 85~265VAC or 100V~370VDC. It features high reliability and robustness withstanding extensive EMI/RFI phenomenon, lighting surge, inductive load switching, high ESD, high fault current environment usually found in Substation, Steel automation, Mining and Process control etc. IES-3424DSFP-2P-PT can run under widely operational temperature (-40°C~75°C) in the harsh environment.

  • System Interface/Performance
    • IEC-61850 & IEEE1613 Compliance
    • 24×10/100TX at/af+ 4 100M/1000M SFP L2+
    • 16K MAC Address Table
    • Dual Power Supply Design for DC(9.5V~60VDC), AC(85V~265VAC) or 100V~370VDC
    • -40to 75C operation temperature(-E model)
    • FAN less design
  • Goose monitoring for port counter of Goose message(IEC packets)
  • MMS server built-in for SCADA monitoring/control
  • User friendly UI, Auto topology drawing, topology demo, Complete CLI for professional setting
  • IP v6/v4 supported
  • Enhanced G.8032 Ring protection in 20ms for single ring
    • Support various ring/chain topologies, including dynamic coupling ring
    • Enhanced G.8032 ring configuration with ease
    • Auto ring configuration(auto mode) for single ring
    • Ring covers multicast on different ports
  • DDM to support SFP diagnostic function***
    • Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance
  • 256 groups MSTP over VLAN
  • VLAN
    • 4K 802.1Q Vlan, Port Based VLAN,GVRP*GMRP*, QinQ*
  • Port Trunk with LACP 14 trunks with automatic link failover
  • LACP link aggregation to add bandwidth
  • QoS (Quality of Service)
    • Supports IEEE 802.1p CoS
    • Per port provides 8 priority queues
    • Port-base,Tag-base and TOS Priority
    • Strict priority and WRR
  • Security
    • SSL/SSH/INGRESS/EGRESS ACL L2/L3
    • Port Security: MAC address entries/Filter/MAC-Port binding
    • IP Security: IP address security management to prevent unauthorized intruder.
    • Management access control with priority
    • Login Security: IEEE802.1X/RADIUS
    • HTTPS for secure access to the web interface
  • Miss-wiring avoidance
    • LED indicator
  • Repowered auto ring restore(node failure protection)
    • Ensure the switches in a ring to survive after power breakout is back
    • The status can be shown in NMS when each switch is back
  • IGMP v1,v2,v3 and Proxy** for Multi Media Application
  • IGMP router to select another Query mode and support IGMP static routing for reversed IGMP flow to bind with port for IP surveillance application
  • Supports IEEE802.1ab LLDP, Cisco CDP
  • DHCP server / client / Port/Vlan based DHCP distribution / DHCP Option 82 supported
  • Mac based DHCP server to assign IP address that includes dumb switches in DHCP network
  • Bandwidth Control
    • Ingress Packet Filter and Egress Rate Limit
    • Broadcast/Multicast Packet Filter Control
  • System Event Log, Email alert, SMS**(mobile text) and SNMP Trap for alarm support
  • TFTP/HTTP firmware upgrade; LantechTM InstaView** for multiple upgrade; USB for edited restoration and auto backup
  • Reset / Factory default button to restore factory setting
  • Watch dog design to reboot switch if CPU is found dead
  • Provides EFT protection ±4K VDC for power line
  • Supports ±8KV contact & 15KV air Ethernet ESD protection
  • 2 DI/DO and 1 relay contact alarm

Hardware Specifications

IEEE Standards IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Ethernet
IEEE802.3z Gigabit fiber
IEEE 802.3x Flow Control Capability
ANSI/IEEE 802.3 Auto-negotiation
IEEE 802.1Q VLAN
IEEE 802.1p Class of Service
IEEE 802.1X Access Control
IEEE 802.1D Spanning Tree
IEEE 802.1w Rapid Spanning Tree
IEEE 802.1s Multiple Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
IEEE 802.1x User Authentication (Radius)
IEEE 1588 Precision Time Protocol v2
Switch Architecture Back-plane (Switching Fabric): 12.8Gbps
Transfer Rate 14,880pps for Ethernet port
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Ethernet / Gigabit Fiber port
Mac Address 16K MAC address table
Jumbo frame 10KB on all ports
Connectors 24 10/100TX RJ-45 with auto MDI/MDI-X function
4 100M / 1000M Mini-GBIC : SFP sockets
RS-232 console: Female DB-9
USB for backup and restore
DDM Conform to SFF-8472 to show diagnostic SFP with temperature, current, voltage, input and output power
LED Per unit: Power 1 (Green), Power 2 (Green), Fault (Red) ,R.M (Green)
Link/Activity (Green), Full duplex/collision(Yellow)), MINI GBIC (Link/Activity )(Green)
Power Supply Two power sockets,
9.5~60VDC input
IEC320 85~265VAC input (-AC model)
AC/DC 85~265VAC/100V~370VDC input (-HV model)
Power Consumption Full load: 30W/ Unload: 13W
Relay Alarm Provides one relay output for port breakdown, power fail and alarm.
Alarm Relay current carry ability: 1A @ DC24V
DI/DO 2 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
2 Digital Output(DO): Open collector to 40 VDC, 200mA
Factory reset button & watch dog design Factory reset button to restore back to factory default settings.  Watch dog design can reboot switch automatically when CPU is found dead
Case Dimension 19” Metal case,IP-30; 440mm(W)x325mm(D)x44mm(H)
Operating Humidity 5%~95% (Non-condensing)
Operating Temperature Standard: -20°C ~60°C
Extended temperature : -40°C ~75°C
Storage Temperature -40°C ~85°C
EMI FCC Class A, CE EN61000-4-2 (ESD),
CE EN61000-4-3 (RS), CE EN-61000-4-4 (EFT),
CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS),
CE EN61000-4-8, CE EN61000-4-11,
CE EN61000-4-12, CE EN55022 Class A, CE EN55024
Stability Testing IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration), IEC60870-2-2, IEC60068-2-30
Power Automation IEC 61850-3, IEEE 1613
MTBF 511,958 hours (standards: IEC 62830)
Warranty 5 years

Software Specifications

Management SNMP v1 v2c, v3/ Web/Telnet/CLI Management
SNMP MIB RFC 1215 Traps MIB,
RFC 1213 MIBII
RFC 1158 MIBII
RFC 1157 SNMP MIB,
RFC 1493 Bridge MIB,
RFC 1573 IF MIB
RFC 2674 VLAN MIB,
Partial RFC 1757 RMON,
RFC 2674 Q-Bridge MIB; Bridge MIB,
LLDP MIB*
RSTP MIB*
Private MIB
VLAN Port based VLAN, up to 28 groups
IEEE802.1Q Tag VLAN
Static VLAN groups up to 256, VLAN ID from 1 to 4096
GVRP up to 256 groups* GMRP*.
Multicast VLAN registration*, QinQ*
Port Trunk with LACP LACP Port Trunk: 8 Trunk groups
LLDP Support LLDP to allow switch to advise its identification and capability on the LAN
CDP Cisco Discovery protocol for topology mapping
Goose monitoring Show individual Goose TX / RX counter(IEC packets)
IEC 61850-9-4 Built in MMS server for data modeling for power SCADA
ITU G.8032 Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode)
Support various ring/chain topologies
Includes dynamic coupling ring
Enhanced G.8032 ring configuration with ease
Ring covers multicast on different ports
PTP v2 Support hardware-based IEEE1588 PTP v2, End to End (2-step) and Peer to Peer (2-step) modes in Transparent Clock, with 4 Dual Speed SFP
User friendly UI
  1. Auto topology drawing with detail node info
  2. DDM threshold monitoring with dB values***
  3. Complete CLI for professional setting
IPv6/v4 Present
Spanning Tree Support IEEE802.1d Spanning Tree,IEEE802.1w Rapid Spanning Tree, IEEE 802.1s MSTP
Quality of Service The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Differentiated Services Code Points – DSCP
Class of Service Support IEEE802.1p class of service, per port provides 8 priority queues
QoS by VLAN Tagged QoS by VLAN for all devices in the network
IP Security Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.
Port Mirror Support 3 mirroring types: “RX, TX and Both packet”
Multicast Filtering & IGMP Support IGMP snooping v1,v2,v3; Supports IGMP static route
IGMP query and router port
1024 multicast groups and IGMP query
Static MAC-Port bridge Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application
Bandwidth Control Support ingress packet filter and egress packet limit.
The egress rate control supports all of packet type,  the limit rates are 0~100Mbps.
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet. The packet filter rate can be set from 0 to 100Mbps
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.
Network Security Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.
802.1X access control for port based and MAC based authentication/MAC-Port binding
Management access control with priority
Ingress/Egress ACL L2/L3
SSL/ SSH for Management
HTTPS for secure access to the web interface
TACACS+* for Authentication
Protection
  1. Miss-wiring avoidance
  2. Repowered auto ring restore (node failure protection)
  3. Loop protection
Flow Control Support Flow Control for Full-duplex and Back Pressure for Half-duplex
System Log Support System log record and remote system log server
SMTP, SMS** Supports SMTP Server and 8 e-mail accounts for receiving event alert; can send SMS** text alert via mobile; Can send alert via mobile SMS** text
SNMP Trap Up to 10 trap stations; trap types including:

  1. Device cold start
  2. Authorization failure
  3. Port link up/link down
  4. DI/DO open/close
  5. Typology change(ITU ring)
  6. PoE ping failure
  7. Power failure
DHCP Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based&VLAN based DHCP distribution (DHCP relay agent)
Mac based DHCP Server Assign IP address by Mac that can include dumb switch in DHCP network
DNS Provide DNS client feature and support Primary and Secondary DNS server.
SNTP Support SNTP to synchronize system clock in Internet
Firmware Update Support TFTP /HTTPS firmware update ; InstaView** mass firmware upgrade**
Configuration backup and restore Support text backup and restore; USB dongle for firmware auto-backup and edited restoration
*Future Release
**Optional
***Optional DDM SFP required
P/N Model name Description
8388-506 IES-3424DSFP-2P-PT 24 10/100TX + 4 Dual SFP L2 plus Industrial IEC61850 Ethernet switch
Built-in 1x isolated DC 12~56VDC power supply + 1x additional PSU slot; -20°C to 60°C
8388-507 IES-3424DSFP-2P-PT-E 24 10/100TX + 4 Dual SFP L2 plus Industrial IEC61850 Ethernet switch
Built-in 1x isolated DC 12~56VDC power supply + 1x additional PSU slot; -40°C to 75°C
8388-510 IES-3424DSFP-2P-PT-AC 24 10/100TX + 4 Dual SFP L2 plus Industrial IEC61850 Ethernet switch
Built-in 1x isolated AC85~265VAC IEC320 power supply + 1x additional PSU slot; -20°C to 60°C
8388-511 IES-3424DSFP-2P-PT-AC-E 24 10/100TX + 4 Dual SFP L2 plus Industrial IEC61850 Ethernet switch
Built-in 1x isolated AC85~265VAC IEC320 power supply + 1x additional PSU slot; -40°C to 75°C
8388-508 IES-3424DSFP-2P-PT-HV 24 10/100TX + 4 Dual SFP L2 plus Industrial IEC61850 Ethernet switch
Built-in 1x isolated AC/DC 85~265VAC/100V~370VDC power supply + 1x additional PSU slot; -20°C to 60°C
8388-509 IES-3424DSFP-2P-PT-HV-E 24 10/100TX + 4 Dual SFP L2 plus Industrial IEC61850 Ethernet switch
Built-in 1x isolated AC/DC 85~265VAC/100V~370VDC power supply + 1x additional PSU slot; -40°C to 75°C

 

OPTIONAL ACCESSORIES – Power for System

Model name Description
EOTH000701 Isolation Power 85-264VAC, 100-370VDC 1.5A, 47-63HZ
EOTH000702 Isolation Power 36-75VDC, 2.5A
EOTH000703 Power 85-264VAC IEC320 socket, 1.5A , 47-63HZ
EOTH000704 Power Input Module 12-56VDC, 2.5A

 

OPTIONAL ACCESSORIES – Mini GBIC (SFP)

Model name Description Model name Description
8330-162X MINI GBIC 1000SX (LC/0.5KM) Transceiver 8330-187 LTSFP-1000BX-20KM Transceiver (WDM 1550)
8330-163X MINI GBIC 1000SX2 (LC/2KM) Transceiver 8330-180 LTSFP-1000BX-40KM Transceiver (WDM 1310)
8330-165X MINI GBIC 1000LX (LC/10KM) Transceiver 8330-182 LTSFP-1000BX-40KM Transceiver (WDM 1550)
8340-0591 MINI GBIC 1000LHX (LC/40KM) Transceiver 8330-181 LTSFP-1000BX-60KM Transceiver (WDM 1310)
8330-166 MINI GBIC 1000XD (LC/50KM) Transceiver 8330-183 LTSFP-1000BX-60KM Transceiver (WDM 1550)
8330-169 MINI GBIC 1000XD (LC/60KM) Transceiver 8330-184 LTSFP-1000BX-80KM Transceiver (WDM 1490)
8330-167 MINI GBIC 1000ZX (LC/80KM) Transceiver 8330-185 LTSFP-1000BX-80KM Transceiver (WDM 1550)
8330-170 MINI GBIC 1000EZX (120KM) Transceiver 8330-071 125Mbps BiDi SFP 2KM (WDM 1310) Transceiver
8330-168 MINI GBIC 10/100/1000T (100m) Transceiver 8330-072 125Mbps BiDi SFP 2KM (WDM 1550) Transceiver
8330-060 100Base FX 2KM, Multi-mode, LC Transceiver 8330-069 125Mbps BiDi SFP 20KM (WDM 1310) Transceiver
8330-065 100Base FX 5KM, Multi-mode, LC Transceiver 8330-068 125Mbps BiDi SFP 20KM (WDM 1550) Transceiver
8330-061 100Base LX 30KM, Single-mode, LC Transceiver 8330-080 125Mbps BiDi SFP 40KM (WDM 1310) Transceiver
8330-197 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1310) 8330-082 125Mbps BiDi SFP 40KM (WDM 1550) Transceiver
8330-198 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1550) 8330-081 125Mbps BiDi SFP 60KM (WDM 1310) Transceiver
8330-195 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1310) 8330-083 125Mbps BiDi SFP 60KM (WDM 1550) Transceiver
8330-196 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1550) 8330-084 125Mbps BiDi SFP 80KM (WDM 1310) Transceiver
8330-188 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1310) 8330-085 125Mbps BiDi SFP 80KM (WDM 1550) Transceiver
8330-189 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1550) 8330-191 Dual Speed SFP 100M/1000M-LX 10KM Transceiver
8330-186 1.25Gbps BiDi SFP 20KM Transceiver (WDM 1310) All SFP P/N# ended with D are with DDM function

DataFEED OPC Suite -2

dataFEED OPC Suite

 La solution “tout en un” pour la communication OPC, ” Big Data” et la connectivité IoT et Cloud.

  • Accès aux Process et Données de Diagnostic aux contrôleurs tels que :  Siemens, Rockwell, B&R, Mitsubishi , grâce au dataFEED OPC Suite
  • Intégration de serveurs OPC dit “Classic” vers des solutions plus modernes comme l’OPC UA “Industrie 4.0“
  • Passerelle MQTT et REST pour l’intégration de données de production vers le cloud IoT et les solutions ” Big Data ” comme : Microsoft IoT, IBM Watson IoT

Simple and Independent Access to Controller Data

  • Read and write access to data in controllers from leading manufacturers
  • Use without modifying control program
  • Easy integration of existing and new controllers into “Industrie 4.0“* solutions
  • Integration of non-OPC UA-capable components, such as Siemens S7 controllers, into OPC UA solutions
  • Cost savings through further use of already existing OPC Classic components
  • Gateway functionality for connecting controllers and components with integrated OPC UA Server to OPC Classic applications

Gateway to Big Data and IoT Clouds Solutions

  • Integration of automation devices in IoT cloud applications using MQTT Publisher functionality, e.g. in IBM Bluemix Cloud
  • State-of-the-art security by SSL/TLS support, including certificates

No Need for DCOM Configuration

  • Integration of automation devices via MQTT Publisher and REST Client functionality in IoT cloud applications, e.g. IBM Watson Cloud or Microsoft IoT Connected Factory
  • Easy integration of production data into NoSQL Big Data storage solutions such as MongoDB
  • State-of-the-art security by SSL/TLS support, including certificates

Easy Configuration

  • Modern, intuitive graphical user interface for fast OPC communication configuration
  • Use of smart hands-on defaults, setup wizards and drag-and-drop support
  • Time savings through effective and efficient configuration of distrubuted automation systems with many OPC UA and OPC Classic Servers

*“Industrie 4.0“ is a German government-driven initiative for implementing an industrial “Internet of Things”

Supported dataFEED Features OPC UA Server and Client, OPC Classic Server and Client, OPC Tunnel, MQTT, MindSphere and REST Connector,
Database Access (SQL/NoSQL), File Access, Data Exchange (in any direction between OPC UA and OPC Classic Servers or controllers), Filter, Optimizer, Concentrator, Bridge, Local Items (in any direction between OPC UA and OPC Classic Clients)
Supported Controllers Siemens SIMATIC S5, SIMATIC S7 (S7-200, S7-300, S7-400, S7-1200, S7-1500, including optimized blocks), LOGO! 8, PAC Counter and Siemens-compatible controllers like VIPA controllers
Rockwell SLC-500, PLC-5, ControlLogix and CompactLogix
Mitsubishi Melsec-Q Series with Ethernet interface card
B&R controllers with Ethernet interface
Modbus TCP-compatible controllers (Wago, Beckhoff, Phoenix, Schneider, etc.)
All controllers and devices with integrated OPC UA Server
Accessible Controller Data Inputs, outputs, data blocks, markers, timers, counters
Supported IoT Devices All devices with integrated MQTT Publisher
Supported OPC Specifications OPC Classic Data Access V1.0a, V2.05, V3.0, OPC Classic XML-DA V1.01,
OPC Alarms & Events V1.10, OPC Unified Architecture V1.02
Supported OPC UAFunctionality Data Access profile

TCP transport protocol using OPC UA binary coding

Security Methods: Basic256SSha256, Basic256

Authentication by user names and passwords including user certificate

Supported OPC Data Types VARIANT Data Types I1, UI1, I2, UI2, I4, UI4, R4, DATE, BSTR, BOOL and arrays (VT_Array) of these data types
Protocols for IoT Cloud Link MQTT Publisher:
MQTT Publisher V3.1.1, V3.1
QoS, Retain, Last Will and Testament
Security SSL/TLS including certificatesMindConnect:
HTTPS
Methoda: POST
Security: SSL including certificates, authentication via Shared Secret or RSAREST Client:
TCP, HTTP, HTTPS
Methods: PUT, POST
Security SSL and user authentification including certificates
Supported Databases NoSQL databases, e.g. MongoDB, CouchDB
ODBC enabled databases, for example, Oracle, MySQL, Microsoft SQL Server, IBM DB2,
other NoSQL- and ODBC-enabled databases upon inquiry
Operation Mode Application (OutProc Server), Windows Service
Logging, Diagnostics Logging of OPC Calls and Notifications, OPC Data, OPC Tunnel frames, text file access, database access, configurable via integrated web server diagnostic interface
Supported Operating Systems Windows 7, Windows 8, Windows 8.1, Windows Embedded 8.1 Industry, Windows 10, Windows 10 IoT Enterprise,
Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Server 2012,Windows Server 2012 R2, Windows Server 2016, Windows Server 2019
Licensing Runtime license per computer
Demo Version Full dataFEED OPC Suite, time limited to 72 hours
LRL-DY-134501 dataFEED OPC Suite, Version 4.01 and higher, including all supported PLC protocols, OPC UA support, access of any number of OPC Tunnel Clients, for simultaneous access to a total of up to 100 OPC UA Servers, OPC Servers and dataFEED OPC Tunnel Servers plus additional functionality like Database Access, File Access, Data Exchange, Optimizer, Concentrator and Bridge
HUA-DD-130001 USB Hardware Key for dataFEED OPC Suite, Version V4.01 and higher, replacing the standard Software Key

Scope of Delivery

Software dataFEED OPC Suite on CD-ROM
Documentation Manual in PDF format and Online Help in English and German

Additional Products and Services

100-1030-01 Training “OPC Server and Client in Practice”
GAA-DX-145111 dataFEED uaGate SI
GPL-CS-191000 echolink S7-compact

dataFEED OPC UA

dataFEED OPC Server Siemens
Serveur OPC Classic  ( Option : Serveur OPC UA ) pour accès facile et rapide aux process et données de diagnostiques sur les PLC Siemens : S5, S7-200, S7-300, S7-400, S7-1200 et S7-150 ainsi  que les controleurs compatible Siemens
dataFEED OPC Server B&R
Serveur OPC Classic ( Option : Serveur OPC UA ) pour l’accès facile et rapide aux process et données de diagnostique sur contrôleurs B&R
dataFEED OPC Server Modbus
OPC Classic Server (optional: OPC UA Server) for fast and easy access to process and diagnostic data in controllers providing a Modbus TCP interface, e.g. controllers from Wago, Schneider Electric or Phoenix Contact
dataFEED OPC Server Rockwell
OPC Classic Server (optional: OPC UA Server) for fast and easy access to process and diagnostic data in Rockwell (Allen-Bradley) CLX, SLC and PLC-5 controllers
dataFEED OPC Server Mitsubishi
OPC Classic Server (optional: OPC UA Server) for fast and easy access to process and diagnostic data in Mitsubishi Melsec-Q controllers

EXTENDED FUNCTIONALITY

dataFEED OPC Tunnel OPC Tunnel for avoiding DCOM communication problems when using OPC Classic for communication between PCs
dataFEED REST Connector REST connectivity for data integration for IoT cloud solutions, support for OPC Classic and OPC UA (optional)
dataFEED MQTT Connector MQTT Publisher functionality for easy and efficient integration of production environments and its data in IoT (internet of Things) and Industrie 4.0* solutions
dataFEED OPC Organizer UA
OPC UA support for implementing Industrie 4.0. Allows using OPC UA (UA) for data exchange within an OPC Classic environment
dataFEED OPC Data Handler Data Handler extension for simple data exchange between controllers and OPC Servers as well as for storing process data in databases and files
dataFEED OPC Organizer Classic OPC Classic Client and OPC Classic Server, for extended OPC Classic communication functionality

For the use of MySQL database, you would need :

You can test you OPC Classical DA with our testing solution

eXport Software

eXport Software – Manage certification projects and create reports

Manage certification projects and create reports for WireXpert and FiberXpert
One Software for both WireXpert and FiberXpert
The eXport reporting software allows the user to centrally manage test results for copper and fiber-optic cables in a single program. Measurement data can be quickly imported with the software from the certification device. A new compressed file format results in small file sizes without loss of detail and allows very fast data exchange. The reports can be saved both as PDF and CSV files. All results from both the WireXpert 4500 and the FiberXpert OTDR 5000 (*. Sor) can be centrally documented. The graphs can display the individual RF parameters documenting and certifying the installed cable’s ability to transmit the customer required Ethernet speeds.

Before a project even begins, cable installation project managers use eXport and the world’s first List-Based Testing tool to generate labels for cables and test labels.  Use the cable label generation tool to quickly generate 1000’s of cable labels to be printed and afixed to your cables and patch panels.  That same list of cables can be downloaded to the WireXpert where you now have a list of tests to run so you can certify cables efficiently in the order you require to complete the job fast.  If a test fails, or cable is not ready to test, move on while the cable is being repaired, select the cable you want to test, and now the job keeps progressing.

Use with both WireXpert and FiberXpert
Capable of reading *.sor and *.flw file format
Export reports to *.csv or *.pdf file format
Import data from local PC, USB drive, or direct from WireXpert
Easy to use
View detailed test results with data plots
Use your own company logo on reports
Available in several languages
Compatible with Windows XP/Vista/7/8

Create certification reports for end customers and for cable warrantees
Manage cable projects before you go into the field: create cable labels to afix to cables.  This simultaneously creates a list of tests to download to the WireXpert to maximize your efficiency with List-based Testing
Increase your productivity and use the eXport software to manage WireXpert 4500 and FiberXpert OTDR 5000 (Bellcore file format)
Create PDF reports and send test results from anywhere

Software
included in WireXpert delivery

EZ Gateway Modbus to BACnet

EZ Gateway Modbus to BACnet

The EZ Gateway Modbus to BACnet (FS-EZX-MOD-BAC) is an easy-to-use, high-performance building and industrial automation protocol gateway for integrators to interface Modbus devices, such as power meters, flow meters, and other Modbus-based controllers, to BACnet networks in commercial buildings, campuses, and industrial facilities. The EZ Gateway supports up to 1000 data points and can connect various flavors of Modbus to BACnet, including:

  • Modbus RTU
  • Modbus TCP/IP
  • BACnet/IP
  • BACnet MS/TP

The EZ Gateway is the quick and easy solution to a system integrator’s Modbus to BACnet integration needs. With the EZ Gateway, the integrator or contractor does not need to be a protocol expert to connect any Modbus device to a BACnet system using either BACnet protocol.

With our long-standing association with the Modbus Organization and total commitment to the Modbus standard, we consistently implement the latest Modbus innovations on our FieldServer protocol gateways and test them thoroughly for interoperability. With tested Modbus features like bit extracting, 32 bit float/integer support, and scaling, our EZ Gateway Modbus to BACnet can work with virtually any Modbus device out of the box. Instant interoperability means that there the devices can be commissioned quickly.

Unparalleled Performance

The EZ Gateway Modbus to BACnet has two RS-485 ports, enabling connection for fewer devices per port, which improves response time. With two RS-485 ports, up to 64 Modbus RTU devices can be connected to the EZ Gateway without the need of adding a repeater to the RS-485 network. Compared to single-port gateways, our dual-port EZ Gateway can reduce the cost of device connectivity or double the speed of connected devices.

The EZ Gateway can connect to 100 Modbus TCP/IP devices via Ethernet. In addition, support for Modbus TCP/IP Concurrent Polling on our EZ Gateway enables faster response time and more devices per segment in situations where the Modbus field devices also support concurrent polling.

1. SMC Device Cloud support

Register your EZ Gateway to the SMC Cloud interface for remote access to local applications, configuration, and device management

2. Modbus Features and Interoperability

Connect with virtually any Modbus device out of the box

  • Modbus Data Manipulation: Efficiently translate between Modbus and BACnet devices through bit extracting
  • Modbus TCP/IP Concurrent Polling: Receive faster response time and support more devices per segment
3. Modbus to BACnet EZ Profiles

Lower commissioning time by uploading preconfigured verified Modbus-BACnet EZ Profiles

4. DeviceProxy™

Minimize management and operational costs with granular visibility and control over each Modbus device from a BACnet management station

5. Dual RS-485 Ports

Improve response time by connecting fewer devices per port or support more devices per gateway

6. Remote Access and Support

All FieldServer gateways come with Remote Access support.  Once registerd to the SMC Cloud, use the Remote Access capability to attach to the FieldServer gateway to monitor, maintain and troubleshoot installed equipment

Model Numbers FS-EZ1-MOD-BAC: 500 point capacity
FS-EZ2-MOD-BAC: 1000 point capacity
Environment Operating Temperature: -40 to 75°C (-40 to 167°F)
Relative Humidity: 5-90% RH non-condensing
Power Requirements 9-30 VDC or 12-24 VAC
Current draw @ 12V:

  • FS-EZx-MOD-BAC: 240 mA
Enclosure Dimensions: 4.5 x 2.9 x 1.6 in. (11.5 x 7.4 x 4.1 cm)
Weight: 0.4 lbs (0.2 Kg)
Other Configuration/Diagnostic utilities
Table, wall, or DIN rail mount
Communication Baud: 4800, 9600, 19200, 38400, 57600, 115200
Start Bit: 7, 8
Stop Bit: 1, 2
Parity: Even, Odd, None
Ethernet: 10/100 BaseT MDIX
Approvals TUV Approved to UL 916, EN 60950-1, EN 50491-3 and CSA C22.2
standards
BTL Certifed, Rev. 12
RoHS Compliant
GOST-R Certified
CE and FCC

FS-EZX-KNX-BAC

EZ Gateway KNX to BACnet

The EZ Gateway KNX to BACnet (FS-EZX-KNX-BAC) is an easy-to-use, high-performance building and industrial automation IIoT gateway for integrators to connect to the cloud and interface KNX certified products to BACnet management systems in commercial buildings, campuses, and industrial facilities. KNX-certified products encompass a wide range of applications such as lighting control, heating, ventilation and air conditioning control, shutter/blind and shading control, alarm monitoring, energy, gas, and water metering, and audio and video distribution. The EZ Gateway KNX to BACnet integrates such KNX-based devices and systems to both flavors of BACnet-based management systems over BACnet MS/TP or BACnet/IP protocols. KNX to BACnet protocol translations include:

KNX to BACnet/IP
KNX to BACnet MS/TP

The EZ Gateway KNX to BACnet is available in 500 and 1000 point count configurations with superior network response times. With the EZ Gateway KNX to BACnet, the integrator or contractor can rely on the product’s interoperable and field-tested protocol implementation, and does not need to be a protocol expert. The integrator can also minimize configuration and commissioning time, while also reducing ongoing operating and maintenance costs.

1. SMC Device Cloud support

Register your EZ Gateway to the SMC Cloud interface for remote access to local applications, configuration, and device management
2. KNX Interoperability

Connect with virtually any KNX-certified device out of the box

ETS Support: Seamlessly import KNX Group addresses from ETS to lower commissioning time

3. BACnet COV

Use the Change of Value (CoV) setting to reduce the amount of BACnet data overhead to allow network traffic to be less congested by transmitting data only when detecting a KNX device status has changed
4. DeviceProxy™

Minimize management and operational costs with granular visibility and control over each KNX device from a BACnet management station
5. Remote Access and Support

All FieldServer gateways come with Remote Access support. Once registerd to the SMC Cloud, use the Remote Access capability to attach to the FieldServer gateway to monitor, maintain and troubleshoot installed equipment

Model Numbers FS-EZ1-KNX-BAC: 500 point capacity
FS-EZ2-KNX-BAC: 1000 point capacity
Environment Operating Temperature: -40 to 75°C (-40 to 167°F)
Relative Humidity: 5-90% RH non-condensing
Power Requirements

9-30 VDC or 12-24 VAC

Current draw: @ 12V

FS-EZX-KNX-BAC: 240 mA

Enclosure Dimensions: 4.5 x 2.9 x 1.6 in. (11.5 x 7.4 x 4.1 cm)
Weight: 0.4 lbs (0.2 Kg)
Other Configuration/Diagnostic utilities
Table, wall, or DIN rail mount
Communication Baud:9600
Start Bit: 8
Stop Bit: 1
Parity:Odd
Ethernet: 10/100 BaseT MDIX
Approvals TUV Approved to UL 916, EN 60950-1, EN 50491-3 and CSA C22.2
standards
BTL Certifed, Rev. 12
RoHS Compliant
GOST-R Certified
CE and FCC

PG-MUX II

Simultaneous Operation of two Devices on one S5 PG Interface

PG-MUX II enables the simultaneous operation of two devices on one S5 PG interface: Connection of programming device, text display, operator panel or other process devices, that understand the PG protocol AS511.

  • Interface doubling for PG connection to a SIMATIC S5
  • Compatible with all S5 controllers including CPU 945. Since physical connection, pin allocation, and the electrical data conform to the PG/PLC interfaces, you can use your regular cables to connect the devices without having to bother with adapters
  • When two PGs are connected to one PLC, all PG functions except “process command” can be executed simultaneously on both PGs
  • Industrial metal housing
  • All interfaces and control elements in the front
  • Including connection cable
PLC Interface TTY (20 mA), active
PG1 + PG 2 Interface TTY (20 mA), active
Protocols 2 x AS511 or
1 x SINEC-L1-Bus
and 1 x AS511
Combinations
  • AS511 (PG Protocol) – AS511 (PG Protocol)
  • AS511 (PG Protocol) – SINEC-L1-BUS
  • SINEC-L1-BUS  – AS511 (PG Protocol)
Power Supply 230 V AC and 24 V DC
Dimensions[in mm] L = 190, D = 110, H = 50
400-9361-05 PG-MUX II, EURO (230V)

Additional Products and Services

400-9361-03 Connection Cable Multiplexer – PLC TTY

People intersted in this product, may be interested in :

S5-TCP/IP-100

Catégories S5

S5 PCLink

Passerelle Ethernet pour contrôleur SIMATIC S5

Integration simple et rapide de la technologie S5 dans une technology Ethernet. Programme ent affichage STEP5  avec capture de données “Process”, en même temps avec un seul controleur. Les données S5 peuvent être accédées directement via SIMATIC S7

csm_S5-PCLink_217e4e4f7f (1)

Space-Saving and Quick to Connect

  • Ultra compact Ethernet gateway in 15-pin D-sub housing
  • Connection to controller via programming interface
  • Powered by controller or external power supply
  • Connection to Ethernet typically via hubs or switches
  • Status display via LED

Easy Configuration for Both Local and Remote Access

  • Support of 10/100 Mbit/s Ethernet with automatic detection
  • IP address assignment either through manual configuration or from DHCP server
  • Connected SIMATIC S5 reachable via Ethernet, directly on site or from remote network computer on the network

Data Integration Without Changes to Control Program

  • Communication synchronized with PLC allowing parallel access to SIMATIC S5 data by multiplexing
  • No need for interrupting application in favour of another
  • STEP5 programming via Ethernet and virtual COM interface
  • Reading and writing of data from SIMATIC S7 controllers supporting TCP/IP PUT/GET without changes to SIMATIC S5 project
  • Optional access to controller data via OPC Server
Supported S5 controllers SIMATIC S5 AG 90U … SIMATIC S5 AG 155U
S5 data types E, A, M, DB, Z, T
PLC interface SIMATIC S5 programming device port, 15-pin connector, 9.6 KBaud
Ethernet interface RJ45, 100 Mbit/s and 10 Mbit/s, automatic detection
Communication types AS511,
RK512 (programming device connection through STEP5 and virtual COM port)
ISO (H1),
ISO on TCP (RFC 1006),
DHCP
IP address Manually configurable, via DHCP server, auto IP
Supported Software Softing S7/S5 OPC Server
Siemens STEP5
OPC Clients, e.g. Citect, InTouch, RSView, WinCC
Power supply 24 VDC, 80 mA, from SIMATIC S5 controller or external
Dimensions (H x W x D) 42 mm x 15 mm x 65 mm
System requirements PC/programming device with Windows 98/Windows NT/Windows 2000/Windows XP and 10/100 MBit Ethernet
S5-PCLink S5-PCLink

Scope of Delivery

Hardware S5-PCLink gateway
Documentation Printed quick reference guide, manual on CD-ROM

S5-PCLink

Step5 displays “Error 0334” when I want to establish a connection via the S5-PCLink

Please download and install the software patch s5vir122.exe from our download area.

I cannot change any settings in the S5-PCLink (e.g. IP address, name, etc….) with the S5-LanManager

Firmware version 1.03 or newer is installed in the S5-PCLink (check S5-LanManager).

Please download an update of the S5-LanManager from our web site. Replace the installed files (C:\Program Files\Softing\S5-PCLink\… ) with those from the S5LanManager_update.zip file.

Communication with the PLC is sporadically broken or cannot be established at all

On S5 PLCs of type S5U115-944 and -928B, the power sources needed by our S5-PCLink are often defective. This is indicated by a failure to connect to the PLC (green LED on S5-PCLink flashes once approx. every 4 seconds) or a broken connection at irregular intervals.

Pinging the S5-PCLink works.

Solution:
You will need a power source adapter that can be added between the PLC and the S5-PCLink, and provides the power sources.
Please contact our sales department if you need this adapter.

What is the default IP address of the S5-PCLinks (factory setting)

There is no default IP address setting. The IP address is automatically assigned by the DHCP server per default.

If there is no DHCP server available, then the module will use a random address from the IP address space 169 – … (after about 1 minute).

In case the device will not be shown in the S5-LAN-Manager then connect it directly with a crossover network cable and your PC. Please disable the Firewall. You can then configure the device in the S5-LAN-Manager. (For the operation mode this function is not necessary).

S5-PCLink is not found in the S5-LAN-Manager

Possible causes:

  • IP address / port is blocked by the firewall . Please disable the firewall and then search again in the S5-LAN-Manager. Ports see below.
  • A virus scanner could also block the communication, so please turn off the virus scanner.
  • There is a router between the PC and the module (especially NAT router), which does not forwards the search to the broadcasts.
  • If a VPN connection is used then the required ports must be free.

 

Ports

  • 65467 (UDP): Search S5-LAN by S5-LAN-Manager/PLCVCOM
  • 65467 (TCP): Search S5-LAN by S5-LAN-Manager/PLCVCOM
  • 10010 (TCP):  PG port ( PLCVCOM )
  • 2002  (TCP): S5 server port ( VIPA )
  • 102   (TCP): S5 server port ( RFC1006)

 

Les personnes intéressées par ce produit peuvent aussi être intéressées par :

THScope ( Logiciel )

Management and Diagnostics for Industrial Networks

TH SCOPE is a software product for industrial network management and network diagnostics. Geared to plant operators and maintenance personnel, TH SCOPE is an all-in-one, easy-to-use solution for permanent monitoring and predictive maintenance, for acceptance testing and for troubleshooting. Combined with TH LINK components, the product supports PROFIBUS, PROFINET, EtherNet/IP and Modbus TCP protocols.
csm_THScope_D_EN_160401_300_9e86a142a3

Versatile Solution for a Wide Variety of Diagnostics Applications

  • Network commissioning, acceptance testing
  • Stationary operation for continuous monitoring
  • Fault localization and identification in case of failure

Comprehensive Representation and Analysis of Diagnostic Data

  • Data on network communication (e.g. load, error statistics)
  • Data from network configuration (e.g. device names, firmware versions, topology)
  • Diagnostic messages (network and device diagnostics)
  • Data collection also from standard Ethernet devices (e.g. PCs or camera systems)

Optimized for Maintenance Users

  • Easy and intuitive handling and operation
  • No expert knowledge of IT or networks required
  • Support of various network protocols (PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP)

Flexible Integration into Existing Systems and Processes

  • Integration of network data into monitoring tools and supervisory control systems via SNMP or OPC
  • Export of all diagnostic data, support of further processing in applications such as Excel
  • Web-based access, local or remote
Functionality
  • Network overview with network and device status plus diagnostic messages with troubleshooting recommendations
  • Analysis of device logs
  • Live list, statistics, inventory
  • GSDML file support, plaintext messages in diagnostic list
  • Topology and trend analysis
  • Automatic e-mail notification in case of fault
  • Reference comparison
  • Acceptance measurements and acceptance reports
  • Data export via Excel
Supported Protocols PROFIBUS (TH SCOPE V2.2),
PROFINET, EtherNet/IP, Modbus TCP (TH SCOPE V2.2 and TH SCOPE V3.0)
Interfaces
  • SNMP Agent
  • OPC Classic DA Server
System Requirements
  • Web browser with Adobe Flash Player 14 or higher
    (for TH SCOPE V2.2, not required for TH SCOPE V3.0)
  • Adobe Reader 8 or higher for reading the documentation and for printing the topology
Supported Operating Systems Windows 7, Windows 8, Windows 8.1,
Windows Server 2008, Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2
Network Access Data collection through TH LINK (PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP and Industrial Ethernet)
Demo Version Full TH SCOPE functionality can be used for free for 30 days after installation
Licensing Via software or hardware key
 Scope of Delivery
Software TH SCOPE (by download from Softing‘s website)
License Software or hardware key
Documentation Installation Manual, User Manual, Release Note
Order Numbers
ATV-LRA-JY-003024 TH SCOPE (software key)
ATV-LRL-JY-003025 TH SCOPE (hardware key)
Additional Products and Services
ATV-GEA-JN-003006 TH LINK PROFIBUS
ATV-GDA-JA-003034 TH LINK PROFINET
ATV-GDA-JY-003037 TH LINK Industrial Ethernet
ATV-LRA-JY-003028 TH LINK PC Industrial Ethernet

TH SCOPE:
If your network is protected by a second firewall in addition to the Windows firewall, make sure that the following settings are made to allow TH SCOPE services to communicate properly.

  • Enabling of HTTP port 80 – inbound and outbound
  • Enabling of SNMP port 161 inbound or port 2367 (if port 161 is used by another SNMP agent).
  • Enabling of IP 224.0.5.128 port 2364 UDP outbound
  • Enabling of UDP ports 2365 outbound and 2366 inbound

 

The following ports are used by TH SCOPE for internal communication only:

  • Port 22
  • Port 80
  • Port 1100
  • Ports 1123 – 1151
  • Port 1500
  • Port 1501
  • Ports 2363 – 2366
  • Ports 49152 – 49171

People interested in this product, can be interested in :

5100-XX-IT

Electrochemical Toxic Gas Sensor Module 5100-XX-IT

Electrochemical Toxic Gas Sensor Module 5100-XX-IT

Sierra Monitor’s fixed 5100-XX-IT gas module monitors toxic gases such as Hydrogen Sulfide (H2S), Carbon Monoxide (CO), Nitrogen Dioxide (NO2), Ammonia (NH3), Oxygen (O2) Deficiency, and others.

The 5100-XX-IT module is based on electrochemical technology, a proven, less-expensive option that offers high accuracy, low power requirements, and sensitivity to a particular gas in the parts-per-million range.

The proven 5100-XX-IT fixed gas sensor module requires calibration only every six months, cutting operating costs and time. As part of the Sentry IT “smart” detector line, the module can be remotely diagnosed and calibrated via Remote Sensor Capability, a valuable asset for toxic gas monitoring. The 5100-XX-IT also offers a three or four wire 4-20mA analog output signal. By integration of IT modules into a Sentry system, the user gains the capability of system Modbus serial communications, extensive diagnostics features, WebServer interface, multiplexed sensor wiring, and field-proven reliability.

The Electrochemical Toxic Gas Sensor Module 5100-XX-IT is approved and certified by a variety of third party agencies, including FM, CE, CSA, SIL-2, ATEX, and IECEx. These approvals and certifications assure our customers that we carry only the highest quality of products and performance.

GlobalCal™

The 5100-XX-IT supports GlobalCal™, our unique global calibration feature of the Sentry IT Controller. This allows a single technician to calibrate connected detectors from the Sentry IT Controller. With GlobalCal, the calibration happens at the controller level. Multiple sensors can be connected to a single controller, allowing groups of sensors to be calibrated at the same time. Standard gas is applied remotely, using permanently installed tubing, rather than direct delivery to the fixed gas detector.

Combined with the six-month calibration interval, GlobalCal reduces labor costs associated with calibration. The need to shut down active process areas for calibration consequently costs facilities thousands of dollars in lost production time. GlobalCal, with its remote and non-intrusive methods, allows production to continue during the calibration process, thus avoiding the costs of lost production. In addition, factory-authorized service technicians performing gas detector calibration save time and costs by remotely calibrating all gas detectors at once from the Sentry IT Controller.

Integral LED Display

Easily calibrate and access gas concentrations, relay statuses, and diagnostics

Internal Continuous Self-Diagnostics

Automatically indicate any fault or optics problems

Menu-Driven System

Rapidly adjust user-friendly configuration of alarm setpoints, calibration, maintenance, and alarm acknowledgment

MODBUS RTU Interface

Provide an easy interface to the world’s most common industrial protocol interface

FM-Approved 6 Month Calibration Interval

Dramatically reduce maintenance time and half the costs as found on others for the user

SMC Sentry Digital Bus Interface

Connect easily with existing Sentry systems that have been in operation for many years

GlobalCalTM support

Non-intrusively calibrate all connected sensors at the same time without declassifying the area

Optional Remote Sensor Configuration

Access the controller over a remote network for convenience or for hard-to-access areas

Optically Isolated 4-20 mA Output

Interface effortlessly with common factory communication links and provide flexibility for the output

HART Interface

Effortlessly communicate over legacy 4-20 mA analog instrumentation wiring

Gas Type Model Std.Range(1) Opt. Max Range Resolution Response Time (2) Accuracy
Operating Range
°F °C RH*
Oxygen (O2) 5100-03-IT 5-25 % Vol 25% Vol 0.1% <10 sec. +/- 0.2%
-4 to 122 -20 to 50 15 – 99%
Carbon Monoxide (CO) 5100-04-IT 0-500PPM 1200 PPM 0.5 PPM <35 sec. +/- 1PPM
-4 to 122 -20 to 50 15 – 99%
Hydrogen Sulfide (H2S) 5100-05-IT 0-100PPM 100 PPM 0.1 PPM <35 sec. +/- 1PPM
-4 to 122 -20 to 50 15 – 99%
Chlorine (Cl2) 5100-06-IT 0-10PPM 10.0 PPM 0.1 PPM <60 sec. +/- 1PPM
-4 to 122 -20 to 50 15 – 99%
Chlorine Dioxide (ClO2) 5100-08-IT 0-3PPM 3.0 PPM 0.1 PPM <60 sec. +/- 1PPM
-4 to 122 -20 to 50 15 – 99%
Sulfur Dioxide (SO2) 5100-10-IT 0-100PPM 100 PPM 0.5 PPM <20 sec. +/- 1PPM
-4 to 122 -20 to 50 15 – 99%
Nitrogen Dioxide (NO2) 5100-12-IT 0-20PPM 20.0 PPM 0.2 PPM <35 sec. +/- 1PPM
-4 to 122 -20 to 50 15 – 99%
Hydrogen Dioxide (H2O2) 5100-21-IT 0-20PPM 20.0 PPM 0.1 PPM <100 sec. +/- 1PPM
-4 to 122 -20 to 50 15 – 99%
Ammonia (NH3) 5100-25-IT 0-100PPM 100 PPM 1.0 PPM <30sec. +/- 1PPM
-4 to 122 -20 to 50 15 – 99%
Hydrogen Fluoride (HF) 5100-26-IT 0-10PPM 10 PPM 0.5 PPM <30 sec. +/- 1PPM
-4 to 122 -20 to 50 15 – 99%
Ethylene Oxide (ETO) 5100-27-IT 0-20PPM 0-20PPM 0.1 PPM <90 sec. +/- 1PPM
-4 to 122 -20 to 50 15 – 99%
1. Optional ranges available *= Non-Condensing
2. Response time to 90% full signal value for applied concentration
Sensor Type Electrochemical
Performance Range:

  • Default range as above
  • User selectable alternative ranges Sensor Life: Typically >2 years

Sensor Life: Typically >2 years

Output Display: Fixed and scrolling LED

Signal Outputs:

  • Sentry digital bus
  • Analog 4-20mA
    • 3-wire non-isolated
    • 4-wire isolated
  • Serial RS-485 Modbus RTU

Relay: Optional

Options Relays:

  • 5 amp Alarm, Warning (0.25 amp Trouble)
  • 5A @ 250 VAC, 5A @ 30 VDC (Alarm, Warning)
  • Board includes auxiliary connection for Sentry multiplexing

HART: Termination board includes HART, MODBUS RS-485, 4-20mA, Digital Input, 2A Relay output, no Sentry bus

Power Power consumption: 2 watts maximum

Input voltage: 24 VDC nominal: 10-30 VDC

Remote Sensor Option 5100-03-IT: 10 feet

5100-04-IT: 15 feet

5100-05-IT: 15 feet

Built-in-Test (BIT) Manual and Automatic
Construction Dimensions: (H x W x D) (differs for 5100-25-IT & 5100-26-IT)

  • A1 & A2: 7.9 x 5.7 x 3.9 in. (20.1 x 14.5 x 9.9 cm)
  • S1 & S2: 7.6 x 4.4 x 4.9 in. (19.3 x 11.2 x 12.4 cm)

Weight:

  • A1 & A2: 3.4 lb. (1.5 Kg)
  • S1 & S2: 7.2 lb. (3.3 Kg)

Housing: Epoxy-coated, die-cast, copper-free aluminum or 316 stainless steel

Rating:

  • Explosion proof, Class 1, Div. 1, Groups B, C, D
  • Group IIB + H2 IP66, IP65, NEMA 4X

Warranty: 2 years

Approvals FM, CSA: For enclosure in hazardous locations

FM Performance Approval (5100-05-IT)

SIL-2 Certified (5100-04-IT, -05, -06-IT)

ATEX Certified II 2 G Ex d IIB+H2 T6 Gb

  • Ta = -20oC to 50oC (5100-05-IT)

IECEx Certified (5100-05-IT)

CE Mark (5100-05-IT)

ABS (5100-05-IT)

CQST Certified for China (5100-03, -04, -05-IT)

CCOE/PESO Certified for India

How to calibrate Sentry IT Gas Sensors with GLobalCal

Sentry IT fire and Gas Detection Solutions