Echochange

echochange

Passerelle Ethernet pour la connexion de différents contrôleurs

The echochange protocol converter supports Ethernet TCP/IP protocols of such leading manufacturers as Siemens, Schneider Electric and Rockwell Automation. This simple protocol conversion makes communication between automation systems of different manufacturers quick and easy.

 

Protocol Conversion for Data Exchange between Multi-Vendor Automation Systems

  • Integration of robust control technology without having to adjust control software
  • Combination of separate networks with different media via configured connections
  • Connection of physically separate networks with different media or heterogeneous networks with identical medium
  • Connection of data from different control systems via allocation tables
  • Bi-directional conversion and writing of PLC data via configured connections
  • Analysis of device functionality and extensive Ethernet diagnostics

Support of Multiple Industrial Standard Protocols

  • Support of TCP, UDP, IP, ISO (H1), ISO on TCP (RFC1006), PLC Header, EtherNet/IP Ethernet protocols
  • Linking of computers with TCP/IP to ISO (H1) networks
  • Remote maintenance of ISO (H1) networked controllers via TCP/IP
  • Routing support for controllers

Investment Protection and IT Maintenance Cost Reduction

  • Standard component for extending functionality without modifying existing systems
  • Very easy configuration through straight-forward project import without requiring control modifications and programming skills
  • Remote configuration and diagnosis via remote maintenance if required
  • No need for additional PC with software updates and additional administration
  • Working for years once configured – untouched, without updates, and with zero maintenance costs
  • Supporting plug-and-go replacement if required based on configuration data stored on SD card
Ethernet Addressable Controllers Siemens S7 and S5, Rockwell Automation ControlLogix, CompactLogix, PLC-5 and SLC-500, Modbus TCP controllers (e.g. Schneider Electric, Phoenix, Contact Wago, Beckhoff), Mitsubishi (Melsec-Q), etc.
Ethernet Protocols TCP/IP, RFC1006 (ISO on TCP), ISO (H1), EtherNet/IP, AB Ethernet, S5, S7, CLX, SLC, Send/Receive (raw data / socket), TCP/IP with PLC header, Modbus TCP, Melsec-Q, DLMS, DCU
Protocol Conversion
  • RFC1006: to ISO(H1), CLX/SLC, AB Ethernet, Melsec-Q, Modbus TCP
  • ISO (H1): to RFC1006, ISO(H1), CLX/SLC, AB Ethernet, Melsec-Q, Modbus TCP
  • Modbus TCP: to RFC1006, CLX/SLC, AB Ethernet, Melsec-Q
Ethernet Interfaces 2xTP (RJ45), 10/100MBit/s
Power Supply 24VDC, ca. 0,3A
Ambient Conditions Operating Temperature: 0 to 55 °C,  Storage Temperature: -20 to 70 °C
Dimensions (HxWxL) 131mm x47mm x 111mm
Weight ca. 0,4kg
Mounting 35mm DIN Rail
Protection Class IP20
Certifications CE, FCC, VCCI
GPL-YY-142101 echochange, Maximum 10 Connections;
Connectors: 2xEthernet
LRA-YY-142001 Upgrade echochange: Maximum 30 Connections

Additional Products and Services

700-5596-04 AC Adapter, 24VDC, Euro, UK, or USA
120-1010-05 Telephone support: application consulting, fees charged on a time and materials basis
110-1000-01 Training “Industrial Ethernet: Troubleshooting in Automation Plants“, 3 days

Scope of Delivery

Hardware Protocol converter echochange, SD Card 2 GB, connector for power supply*
Software Configuration software NetCon on CD-ROM
Documentation Quick Start leaflet, integrated help , product manual on CD-ROM

* A plug-in powerpack is not included. If necessary, please order this separately.

Pour des formations sur l’echochange, veuillez nous contacter

Connector Power Pack 24 V DC

Country-specific connector power packs are available. Note: A connector power pack is not included in the delivery of the echochange. If necessary please order it separately.

Technical Details

100 – 240 V AC, 47 – 63 Hz, sec. 24 V, 1,25A

dataFEED OPC Classic SDK

dataFEED OPC Classic SDK

dataFEED OPC Classic SDK / OPC DA SDK

  • OPC Classic Softing pour communication avec les environnements “Automatisme”
  • Interface de programmation d’applications optimisée
  • Fonctionalités étendues; disponibles sous forme de librairies

Performance éprouvée

  • Continuously enhanced since 1997 in response to evolving technologies
  • In use in several thousand OPC products at more than 1,600 companies around the world
  • Ideal for time-critical control tasks as well as complex projects comprising several hundred thousand items
  • Fitting to wide range of Windows development environments and target systems

Interface d’intégration facile et rapide

  • Intuitive C++ and .NET API
  • Integrated wizards for easy application generation
  • Quick start with easy-to-understand documentation, tutorial and sample projects

Mise en service de votre application : très rapide

  • Extensive OPC DA and OPC AE library, adapted to customer requirements
  • Automatic generation of OPC project
  • Complete functionality for accessing OPC Namespace or Event Area, OPC Items as well as for event and method call handling
  • Only implementation of product-specific business logic required, no need to learn details of OPC specifications or DCOM and SOAP technologies
  • Saving of several months of work
OPC Specifications OPC Data Access V1.0a, V2.05, V3.0, OPC Alarms & Events V1.10
OPC Roles OPC Client, OPC Server
OPC Transport DCOM for OPC Data Access and Alarms & Events
OPC Security Partial Support of OPC Security Custom Interface V1.00
Programming Interface C++, C#, Visual Basic .NET
Development Environment Microsoft Visual Studio 2008, Microsoft Visual Studio 2010, Microsoft Visual Studio 2012,
Microsoft Visual Studio 2013, Microsoft Visual Studio 2015, Microsoft Visual Studio 2017,
.NET Framework 3.5, .NET Framework 4.0, .NET Framework 4.5, .NET Framework 4.6
Development Operating Systems Windows 7, Windows 10
Windows Server 2008 RS2, Windows Server 2012
Target Operating Systems* Windows 7 (32 Bit, 64 Bit), Windows 8 (32 Bit, 64 Bit), Windows 10,
Windows Server 2003, Windows Server 2008 RS2, Windows Server 2012, Windows Server 2016
OPC Compliance / Certification OPC Foundation Test Lab certification for Demo Server and Demo Client
Regularly tested at OPC Foundation Interoperability Workshops
Successful pass of test with OPC Foundation Compliance Test Tool
Programming Support Wizard for automatic creation of OPC Client or OPC Server framework application
Comprehensive programming samples and tutorials
OPC Demo Client and Server with unlimited functionality and unlimited runtime available for testing and demonstration purposes
Trial Version Trial toolkit assemblies contain the complete functionality. Limitation to 90-minute runtime period applies.
Trial version upgrades to unlimited functionality in binary format simply by using the binary license activation key
Licensing Single Seat Developer License for specific OPC Toolkit features in source and binary Format
OPC-enabled applications based on source or binary format license can be deployed without limitations

* Please contact your sales representative for support of different compilers or operating system variants.
dataFEED OPC Classic SDKs are known to work on several platforms such as Windows CE, Linux, VxWorks, etc.

WRL-DD-034101 / WQL-DD-034201 Client OPC DA Classic : licence développeur “toolkit”, format binaire /  format source
WRL-DD-034111 / WQL-DD-034211 Client OPC AE Classic : licence développeur “toolkit”, format binaire /  format source
WRL-DD-034102 / WQL-DD-034202 Serveur OPC DA Classic : licence développeur “toolkit”, format binaire /  format source
WRL-DD-034112 / WQL-DD-034212 Serveur OPC AE Classic : licence développeur “toolkit”, format binaire /  format source
SIA-DD-030400 Services d’intégration sur plateforme choisi par le client
LEA-DD-030300 Licence “Site extension”  pour  dataFFED OPC SDKs
LMA-DD-034000 Service et contrat de support pour le dataFFED OPC Classic SDKs

  • dataFEED OPC SDK, Client DA, format binaire : LMA-DD-034000-034101
  • dataFEED OPC SDK, Client AE, format binaire : LMA-DD-034000-034111
  • dataFEED OPC SDK, Serveur DA, format binaire : LMA-DD-034000-034102
  • dataFEED OPC SDK, Serveur AE, format binaire : LMA-DD-034000-034112

Ce que vous recevrez…

Logiciel Logiciel à installer OPC Toolkits SDK sur DVD-ROM. Installation disponible également par téléchargement
Support Support technique dédié
Documentation “Online Help” en anglais au format CHM, que vous retrouverez sur l’installation su logicieml

Produits additionnels et services:

OPC-ENTW-TAG OPC engineering / consulting /  assistance

IGS-5408DFT-PT

2* 10/100/1000T + 2 100/1000 SFP + 8 10/100/1000T IEC-61850-3 Industrial Managed Ethernet Switch w/ Enhanced G.8032 Ring & MMS, LTDP**, PTPv2

  • Compliant with IEC61850-3 & IEEE1613
  • Supports PTP IEEE1588v2 two-step on Giga ports
  • Built-in MMS server based on IEC61850-90-4 switch data modeling for SCADA with monitoring and control
  • IEC packet counter for GOOSE monitoring
  • QoS for GOOSE packet**
  • LTDP** (Link Train Discovery Protocol) to auto-assign IP as well as inherit the configuration in replaced switch
  • Enhanced G.8032 ring protection < 20ms for single ring. Supports auto mode, enhanced mode, train mode, multi-VLAN and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16MSTI / RSTP; support MRP ring**
  • Miss-wiring avoidance & node failure protection
  • User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***; Complete CLI
  • Support LACP link aggregation, IGMP v3/router port, DHCP server & DHCP Option82; Port based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH/SSL, HTTPS, INGRESS/EGRESS ACL L2/L3, TACACS+*, QinQ**, SMS**
  • Protocol based VLAN** ; IPv4/IPv6 Subnet based VLAN**
  • Environmental Monitoring for temp, voltage and current
  • Wide range dual DC input from 36V~72V with galvanic isolation
  • Optional InstaView** for centralized backup, editing the configuration file and upgrade firmware
  • USB port to backup, restore the configuration file and upgrade firmware (-U model)

Lantech IGS-5408DFT-PT is a high performance L2+ (Gigabit uplink) switch with 8 10/100/1000T + 2 10/100/1000T + 2 Dual Speed SFP that complies with IEC 61850-3 & IEEE 1613. It delivers ITU G.8032 enhanced ring recovery less than 20ms in single ring while also supports train ring, enhanced mode, multiple VLAN model with easy configuration.

The built-in MMS server allows SCADA to control & monitor switch for data modeling, it also support hardware 2 step PTP (Precision Time Protocol) with IEEE 1588v2 standard.

GOOSE monitoring packet counter; Built-in MMS server for IEC61850 data modeling for monitoring and control Optional QoS for GOOSE packet
The exclusive GOOSE monitoring function (IEC packet) can display the counter of GOOSE message transmitted and received by port.

The built-in MMS (Manufacturing Messaging Specification) server can help SCADA to monitor and control switch by data modeling. It covers system, power, port status, environmental monitoring, network configuration.

Optional QoS scheme for Goose packet to ensure low latency in the data patch.

LTDP**(Link Train Discovery Protocol) for zero- touch maintenance
Lantech IPGS-5208GF (IP67/IP54) features LTDP protocol in single ring topology that can help to get the same IP for replaced switch or restore the same configuration with zero-touch.

Miss-wiring avoidance, Repowered auto ring restore, Loop protection
The IGS-5408DFT-PT also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IGS-5408DFT-PT is able to alert with the LED indicator and disable ring automatically. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.

Enhanced G.8032 ring, 16 MSTI MSTP; Optional MRP ring**
Lantech IGS-5408DFT-PT features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring, multiple-VLAN ring and auto-ring with easy setup. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows spanning tree over VLAN for redundant links with 16 MSTI.

DHCP option 82 & Port based, Mac based DHCP, Option66, IPv6 DHCP server**
DHCP option 82 and Port based DHCP function can offer the same IP address on port base or VLAN base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The built-in DHCP Option 82 server offers the convenience of policy setting on the switch. Mac based DHCP server function assigns an IP address according to its MAC address to include dumb switches in DHCP network. DHCP option 66 is also supported. Optional IPv6 address resolution for DHCP server can be supported.

QoS by VLAN for legacy devices
QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.

QinQ**, QoS QinQ** and GVRP** supported
It supports the QinQ**, QoS QinQ**, GVRP** for large VLAN segmentation.

IGMPv3, GMRP**, router port, static multicast forwarding and multicast Ring protection
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP**, router port and static multicast forwarding binding by ports for video surveillance application.

User friendly GUI, Auto topology drawing
The user friendly UI, innovative auto topology drawing and topology demo makes IGS-5408DFT-PT much easier to get hands-on. The IGS-5408DFT-PT supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.

Editable configuration file; USB port for configuration upload & download; InstaView** for mass deployment
The configuration file of Lantech IGS-5408DFT-PT can be exported and edited with word processor for the other switches configuration with ease. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead.

The built-in USB port can have configuration upload & download by USB dongle.

With optional InstaView, the configuration files can be mass backup, mass-editable deployed and auto upgrading firmware in batch make maintenance easy.

Event log & message; 2 DI / 2 DO
In case of event, the IGS-5408DFT-PT is able to send an email & SMS** text message to pre-defined addresses as well as SNMP Traps our immediately. It provides 2 DI and 2 DO. When disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.

Environmental monitoring for switch inside information
The environmental monitoring can detect switch overall temperature, voltage and current where can send the SNMP traps, email and SMS** alert when abnormal.

Wide range dual DC powered input with galvanic isolation; Relay contact alarm
The Lantech IGS-5408DFT-PT is designed with wide range dual power input from 18V~72VDC with galvanic isolation. Featured with relay contact alarm function, the IGS-5408DFT-PT is able to connect with alarm system in case of power failure or port disconnection. The IGS-5408DFT-PT also provides ±2500V EFT, ±4000V Surge and ±8000V ESD air protection, which can reduce unstable situation caused by power line and Ethernet.

Industrial hardened design for extended temperature operation
Lantech IGS-5408DFT-PT features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.

  • 8 10/100/1000T + 2 10/100/1000T + 2 Dual Speed SFP (Total 12 Ports Switch)
  • Back-plane (Switching Fabric): 24Gbps
  • 16K MAC address table
  • Built-in MMS server for SCADA data-modeling with control and monitoring
  • System info
  • Environmental monitoring
  • Power
  • Device event report
  • Port status
  • Port statistic
  • Port event report
  • Firmware upgrade
  • Network configuration
  • Two-step hardware PTP compliant with IEEE 1588 v2 for Gigabit ports
  • Optional QoS for Goose packet
  • DDM to support SFP diagnostic function***
    • Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance
  • 10KB Jumbo frame
  • User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting
  • Enhanced G.8032 Ring recovery < 20ms in single ring
    • Support various ring/chain topologies, including train ring, enhanced ring, basic ring, auto ring & multiple VLAN ring
    • Enhanced G.8032 ring configuration with ease
    • Auto ring configuration(auto mode) for single ring
    • Covers multi-cast and data packets
  • Provides EFT protection ±2500 VDC for power line.
  • Supports ±8000 VDC ESD air protection
  • ±4000V Surge for signal port
  • provides 8 priority queues Port base, Tag Base and Type of Service Priority
  • IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy with with 16 MSTI
  • 4K 802.1Q VLAN, Port based VLAN, GVRP*, QinQ*, QoS QinQ*
  • Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console/ LantechTM InstaView**
  • DHCP server / client / DHCP Option 82 relay / DHCP Option 82 server Port based DHCP server; DHCP Option 66; IPv6 address resolution for DHCP server**
  • Mac based DHCP server to assign IP address that includes dumb switches in DHCP network
  • Bandwidth Control
    • Ingress packet filter and egress rate limit
    • Broadcast/multicast packet filter control
  • Relay alarm output system events
  • Miss-wiring avoidance
    • LED indicator
  • Repowered auto ring restore
    • Ensure the switches in a ring to survive after power breakout is back
    • The status can be shown in NMS when each switch is back
  • TFTP/ SFTP**/HTTP firmware upgrade; LantechTM InstaView** for multiple upgrade
  • Configuration backup and restoration
    • Supports text configuration file for system quick installation
    • USB port for upload / download configuration by USB dongle
    • InstaView** for centralized configuration deployment, backup & upgrade
  • System Event Log, SMTP Email alert, SMS** mobile (text) and SNMP Trap for alarm support; 32 RMON counters
  • Security
    • SSL/SSH/INGRESS/EGRESS ACL L2/L3
    • Port Security: MAC address entries/Filter/MAC-Port binding
    • IP Security: IP address security management to prevent unauthorized intruder.
    • TACACS+*
    • Login Security: IEEE802.1X/RADIUS
    • HTTPS for secure access to the web interface
  • Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application
  • Multicast static route for non- IGMP camera to prevent flooding; IGMP router port to assign query in ring for reversed multicast video flow
  • IGMPv1,v2,v3 with Query mode for multimedia; GMRP**
  • Factory reset button to restore setting to factory default
  • Watchdog design to auto reboot switch CPU is found dead
  • LTDP** (Link Train Discovery Protocol) with Port based DHCP can assign the same IP address and configuration to replacing switches in single ring. It can also keep the config file when switches being swapped
  • Supports DIDO (2 Digital Input / 2 Digital Output)
  • Wide range dual input power from 36V to 72V with galvanic isolation
  • Environmental monitoring for system input voltage, current and ambient temperature.
  • IP30 metal housing with DIN rail and Wall-mount** design

Hardware Specifications

Standards IEEE802.3 10Base-T Ethernet
IEEE802.3u 100Base-TX
IEEE802.3ab 1000Base-T Ethernet
IEEE802.3z Gigabit fiber
IEEE802.3x Flow Control and Back Pressure
IEEE802.3ad Port trunk with LACP
IEEE802.1d Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1s Multiple Spanning Tree
IEEE802.3ad Link Aggregation Control Protocol (LACP)
IEEE802.1AB Link Layer Discovery Protocol (LLDP)
IEEE802.1X User Authentication (Radius)
IEEE802.1p Class of Service
IEEE802.1Q VLAN Tag
IEEE1588 Precision Time Protocol v2
Switch Architecture Back-plane (Switching Fabric): 24Gbps
Transfer Rate 14,880pps for Ethernet port
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Ethernet / Gigabit Fiber port
Mac Address 16K MAC address table
Jumbo frame 10KB
Connectors 10/100/1000T:10 x ports RJ-45 with Auto MDI/MDI-X function
Mini-GBIC: 2 x 100/1000 SFP socket with DDM
RS-232 connector: RJ-45 type
USB x 1 (-U model)
Power & Relay connector: 1 x 6-pole terminal block
DIDO : 1 x 6-pole terminal block
Network Cable 10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
1000Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
Optical Cable 1.25Gbps:
Multi mode: 0 to 550 m, 850 nm (50/125 μm); 0 to 2 km, 1310 nm (50/125 μm)
Single mode: 0 to 10 km/ 30 km/ 40 km, 1310 nm (9/125 μm); 0 to 50 km/ 60 km/ 80km/ 120 km, 1550 nm (9/125 μm)
125Mbps:
Multi mode: 0 to 2 km/ 5 km, 1310 nm (62.5/125 μm)
Single mode: 0 to 30 km, 1310 nm (62.5/125 μm)
WDM 1.25Gbps:
Single mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1310 nm (9/125 μm); 0 to 80 km, 1490 nm (9/125 μm); 0 to 10 km/ 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)
WDM 125Mbps:
Single mode: 0 to 20 km/ 40 km/ 60 km/ 80 km, 1310 nm (9/125 μm); 0 to 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)
LED Per unit: Power 1 (Green), Power 2 (Green), FAULT (Red), RM(Green)
Ethernet port: Link/Activity (Green), Speed (Green); Mini-GBIC: Link/Activity (Green)
DI/DO 2 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
2 Digital Output(DO): Open collector to 40 VDC, 200mA
Operating Humidity 5% ~ 95% (Non-condensing)
Operating Temperature -20°C~60°C / -4°F~140°F (Standard model)
-40°C~75°C / -40°F~167°F(-E model)
Storage Temperature -40°C~85°C / -40°F~185°F
Power Supply 36 to 72 VDC with galvanic isolation
Power Consumption 10W
Case Dimension Metal case. IP-30,
74 (W) x 105 (D) x 152 (H) mm
Weight 900 g
Installation DIN Rail and Wall Mount** Design
EMI & EMS FCC Class A,
CE EN55032, CE EN55024,
CE EN61000-4-2, CE EN61000-4-3,
CE EN61000-4-4, CE EN61000-4-5,
CE EN61000-4-6, CE EN61000-4-8,
CE EN61000-6-4, CE EN61000-6-2
Stability Testing IEC60068-2-32 (Free fall),
IEC60068-2-27 (Shock),
IEC60068-2-64 (Vibration)
Railway verification EN50121-4 , EN55022 (EMV),
EN50125-3 (environmental conditions)
Substation Verification IEC 61375
MTBF 830,589 hrs
Warranty 5 years

Software Specifications

  • 8 10/100/1000T + 2 10/100/1000T + 2 Dual Speed SFP (Total 12 Ports Switch)
  • Back-plane (Switching Fabric): 24Gbps
  • 16K MAC address table
  • Built-in MMS server for SCADA data-modeling with control and monitoring
  • System info
  • Environmental monitoring
  • Power
  • Device event report
  • Port status
  • Port statistic
  • Port event report
  • Firmware upgrade
  • Network configuration
  • Two-step hardware PTP compliant with IEEE 1588 v2 for Gigabit ports
  • Optional QoS for Goose packet
  • DDM to support SFP diagnostic function***
    • Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance
  • 10KB Jumbo frame
  • User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting
  • Enhanced G.8032 Ring recovery < 20ms in single ring
    • Support various ring/chain topologies, including train ring, enhanced ring, basic ring, auto ring & multiple VLAN ring
    • Enhanced G.8032 ring configuration with ease
    • Auto ring configuration(auto mode) for single ring
    • Covers multi-cast and data packets
  • Provides EFT protection ±2500 VDC for power line.
  • Supports ±8000 VDC ESD air protection
  • ±4000V Surge for signal port
  • provides 8 priority queues Port base, Tag Base and Type of Service Priority
  • IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy with with 16 MSTI
  • 4K 802.1Q VLAN, Port based VLAN, GVRP*, QinQ*, QoS QinQ*
  • Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console/ LantechTM InstaView**
  • DHCP server / client / DHCP Option 82 relay / DHCP Option 82 server Port based DHCP server; DHCP Option 66; IPv6 address resolution for DHCP server**
  • Mac based DHCP server to assign IP address that includes dumb switches in DHCP network
  • Bandwidth Control
    • Ingress packet filter and egress rate limit
    • Broadcast/multicast packet filter control
  • Relay alarm output system events
  • Miss-wiring avoidance
    • LED indicator
  • Repowered auto ring restore
    • Ensure the switches in a ring to survive after power breakout is back
    • The status can be shown in NMS when each switch is back
  • TFTP/ SFTP**/HTTP firmware upgrade; LantechTM InstaView** for multiple upgrade
  • Configuration backup and restoration
    • Supports text configuration file for system quick installation
    • USB port for upload / download configuration by USB dongle
    • InstaView** for centralized configuration deployment, backup & upgrade
  • System Event Log, SMTP Email alert, SMS** mobile (text) and SNMP Trap for alarm support; 32 RMON counters
  • Security
    • SSL/SSH/INGRESS/EGRESS ACL L2/L3
    • Port Security: MAC address entries/Filter/MAC-Port binding
    • IP Security: IP address security management to prevent unauthorized intruder.
    • TACACS+*
    • Login Security: IEEE802.1X/RADIUS
    • HTTPS for secure access to the web interface
  • Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application
  • Multicast static route for non- IGMP camera to prevent flooding; IGMP router port to assign query in ring for reversed multicast video flow
  • IGMPv1,v2,v3 with Query mode for multimedia; GMRP**
  • Factory reset button to restore setting to factory default
  • Watchdog design to auto reboot switch CPU is found dead
  • LTDP** (Link Train Discovery Protocol) with Port based DHCP can assign the same IP address and configuration to replacing switches in single ring. It can also keep the config file when switches being swapped
  • Supports DIDO (2 Digital Input / 2 Digital Output)
  • Wide range dual input power from 36V to 72V with galvanic isolation
  • Environmental monitoring for system input voltage, current and ambient temperature.
  • IP30 metal housing with DIN rail and Wall-mount** design
*Future Release
**Optional
***Optional DDM SFP required

pnGate PA

Passerelle PROFINET vers PROFIBUS PA (pnGate PA)

Intégration de segments PROFIBUS PA dans un sytème de contrôle PROFINET

  • Ré-utilsez vos power Conditioner dans une technologie plus avancée ?
  • Pas de segments PROFIBUS DP intermédiaires.
  • Préparé pour une intégration standard et pour les outils d’administration

Passerelle PROFINET : La clef essentiel pour une transition vers des technologies de pointe.

  • Passerelle PROFINET : Simple replacement des coupleurs PROFIBUS PA/DP
  • Ré-utilsation des segments PROFIBUS PA sans aucune modification
  • Support de la redondance PROFINET, afin d’accroitre la fiabilité.

Connexion directe aux segments PROFIBUS

  • Cette passerelle PROFINET/PROFIBUS PA est assimilé à un device PROFINET et un maître PROFIBUS PA
  • Supporte jusqu’à 4 segments PROFIBUS PA

Configuration, paramétrisation et outils d’administration aux Standard en vigeur pour cette passerelle PROFINET / PROFIBUS PA

  • Supporte  les outils PROFINET tels que: TIA Portal, Step7 et PC WORXS
  • Incluant  CommDTM et permettant l’utilisation d’applications FDT/DTM
  • Parametrisation EDD possible via Simantic PDM
Technical Details
Hardware Processor
Status LEDs (Gateway)Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9
PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update)
SF (system fault), BF (bus fault)
Interfaces and Connectors Ethernet

PROFIBUS PA

2 * IEEE 802.3 100BASE-TX / 10BASE-T, embedded PROFINET switch for daisy chain topology
Connectors: RJ45
Protocol: PROFINET RT / IRT, Support of PROFINET redundancy protocols
RESTful API interface for device configuration
Up to 4 PROFIBUS PA (MBP) segments (refer to the section “Order Numbers”),
Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC … 32 VDC,
current consumption 10 mA,
Connectors: 3-position screw connection, galvanically isolated
Physical Properties Dimensions (H x W x D)
Weight
Power SupplyOperating / Storage Temperature
Relative Humidity
Cooling
Coating
Mounting
Protection Class
100 mm x 35 mm x 105 mm
About 0.25 kg
18 VDC … 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
No power supply to PROFIBUS PA segments through pnGate PA
-40 °C … +70 °C / -40 °C … +85 °C
(see detailed mounting description in user manual)
10 % … 95 %, non-condensing
Convection, no fan
Conformal coating based on ANSI / ISA-S71.04 G3
DIN rail 35 mm
IP20
Scope of Delivery
Hardware pnGate PA Gateway
Software GSDtoGSDML Converter, FDT CommDTM, PACTware, Drivers and Tools
Documentation On CD-ROM
Order Numbers
GCA-AL-024602 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PAsegments (up to 32 PA devices).
GCA-AL-024604 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PAsegments (up to 64 PA devices).
GCA-AL-024605 pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices). For reversed mounting position on STAHL backplane.
Additional Products and Services
GCA-EL-024802 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices).
GCA-EL-024804 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices).

Les personnes intéressés par ce produit, peuvent aussi être intéressés par : 

  • pnGate PB : PROFINET to PROFIBUS Gateway. Supports up to 2 PROFIBUS PAsegments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).

FMB110

GNSS/GSM/Bluetooth tracker avec antennes GNSS/GSM internes

FMB110: Tracker GNSS/GSM/Bluetooth avec antennes internes. Pas de batterie

FMB110 small and professional tracker with internal high gain GSM and GNSS antennas, which is able to collect device coordinates and other useful data and transfer them via GSM network to server. This device is perfectly suitable for applications where location acquirement of remote objects is needed: fleet management, car rental companies, taxi companies, public transport, logistics companies, personal cars and so on. FMB110 can perform tasks on remote objects, such as monitoring engine status, controlling truck’s door etc.

New GNSS module

New generation GSM/GNSS module

With new integrated GSM/GNSS module, your tracking experience will be better than ever before. Even higher sensitivity, faster than ever cold start and almost instant hot start ensures that your fleet will be tracked precisely.

Bluetooth icon

Bluetooth

Integrated Bluetooth 4.0 LE allows usage of  various wireless sensors and  grants compatibility with previously available Bluetooth V3.0 features like device configuration, firmware update, headset support. Retrieve temperature and humidity information from Bluetooth sensors without the need of wired connection – reduce installation costs. Save on fuel by reducing aggressive driving, increase your driver safety and reduce the number of driving-related incidents with Android application BTAPP.

Various vehicle CAN data

Various vehicle CAN data

With additional Teltonika Vehicle CAN adapters you will be able to acquire CAN data from any kind of transport such as light vehicles, trucks, buses, agriculture transport, and special transport. Supported vehicles list contains more than 1800 models.

1-Wire

1-Wire

1-wire protocol support enables you to identify your drivers and connect up to 4 temperature sensors. According to iButton or RFID ID you can prevent unauthorized access to your fleet and temperature sensors allows you to monitor your cargo.

FMB110 scheme

GSM:

  • Quad-band 900/1800 MHz; 850/1900 MHz
  • GPRS Multi-Slot Class 12 (up to 240 kbps)
  • GPRS Mobile Station Class B
  • SMS (text/data)
  • Dual-SIM (1 x micro SIM card, 1 x eSIM)

Bluetooth:

  • Bluetooth specification V4.0
  • Bluetooth transceiver fully compliant with Bluetooth specification V4.0 for external peripherals:
    • Voice calls over Bluetooth
    • Configuration via Bluetooth
    • OBDII Bluetooth dongle
    • Various BLE sensors support Temperature, Humidity etc.

 GNSS:

  • Tracking: 33/ 99 acquisition channels
  • -165 dBM sensitivity
  • Hot start <1s
  • Warm Start < 25s
  • Cold start < 35s
  • NMEA-183 protocol
  • GPS, GLONASS, GALILEO, BEIDOU, SBAS, QZSS, DGPS, AGPS
  • Accuracy < 3m

INTERFACE:

  • 2 Digital Inputs (1 reserved for Ignition Status Monitoring)
  • 1 Analog Input (10V or 30V range)
  • 1 configurable input DIN3 or AIN2
  • 2 Digital Open-collector Outputs (connecting external relays, LED, buzzers etc.)
  • 1-Wire® (iButton® , RFID, temperature sensors)
  • Built in accelerometer
  • Power supply (+10…+30) V DC
  • Internal high gain GSM antenna
  • Internal high gain GNSS antenna
  • Dimensions: L(65mm) x W(56,6mm) x H(18,9mm)
  • 2 Status LEDs
  • Micro USB Port

FMB110BBV801 Contenu du package “Standard”

  • 10 pcs FMB110 tracker
  • 10 pcs Input/output power supply cable (0.9 m)

FMB110BB4R01 Contenu du package

  • FMB110 tracker
  • Input/output power supply cable (0.9 m)

FMB110BB7201: Contenu du package

  • FMB110 tracker
  • Input/output power supply cable (0.9 m)
  • micro USB-USB cable (0.8 m)

Multi IR Flame Detector 3600-M

Multi IR Flame Detector 3600-M

he 3600-M uses infrared (IR) technology, a reliable design that provides early warning of flaming fires and immunity to false alarms from IR sources such as sunlight and IR projectors.

The 3600-M utilizes a Multi-Spectrum Design, allowing it to detect hydrocarbon and hydrogen flames up to 215 feet away. It can detect a gasoline pan fire at 215 feet or a hydrogen flame at 100 feet in less than 5 seconds. Users can also select different sensitivity levels to ensure no other detectors cross-over detection zones. Other features include a heated window to eliminate condensation and icing, HART and Modbus capabilities for digital communications, low power requirements, and a compact design.

The Multi IR Flame Detector 3600-M is approved and certified by a variety of third party agencies, including FM, ATEX, IECEx, TUV, and CSA. These approvals and certifications assure our customers that we carry only the highest quality of products and performance.

1. MULTI-SPECTRUM DESIGN

Detect hydrocarbon and hydrogen flames up to 215 feet away

2. IR SENSITIVITY SELECTION

Choose between short and long distance sensitivity ranges, depending on the needs and function

3. 5-SECOND RESPONSE

Quickly respond and alarm users of a fire in a swift manner

4. HEATED WINDOW

Eliminate any possible condensation or icing to ensure the detector to function properly

5. LOW POWER REQUIREMENTS

Save energy costs while protecting the facility

6. MULTIPLE OUTPUT OPTIONS (RELAY OUTPUTS, 0-20 MA, HART, MODBUS RS-485)

Easily install in a variety of field applications and easily obtain critical safety information wherever needed with maximum flexibility and compatibility

Model Number 3600-M
Spectral Response Multi IR Bands
Detection Range (At highest Sensitivity Setting for 1 sq. ft. / 0.1 sq. m pan fire)

215 ft. (65 m) n-Heptane
215 ft. (65 m) Gasoline
150 ft. (45 m) Diesel F
150 ft. (45 m) JP5
100 ft. (30 m) Hydrogen
150 ft. (45 m) Kerosene
135 ft. (40 m) Ethanol
115 ft. (35 m) Methanol
135 ft. (40 m) IPA (Isopropyl Alcohol)
100 ft. (30 m) Methane*
100 ft. (30 m) LPG*
16 ft. (5 m) Polypropylene Pellets
33 ft. (10 m) Office Paper

*20” (0.5 m) high, 8” (0.2 m) with plume fire

Response Time Typically 5 seconds
Adjustable Time Delay Up to 30 seconds
Sensitive Range 4 Sensitive Ranges for 1 sq. ft. (0.1 sq. m) n-heptane pan fire from 50 ft. (15 m) to 215 ft. (65 m)
Field of View Gasoline: 67o horizontal, 70o vertical

Hydrogen: 80o horizontal, 80o vertical

Built-in-Test (BIT) Manual and Automatic
Temperature Range Operating: -67oF to 167oF (-55oC to 75oC)

Operating Option: -67oF to 185oF (-55oC to 85oC)

Storage: -67oF to 187oF (-55oC to 85oC)

Humidity Up to 95% non-condensing (withstands up to 100% RH for short periods)
Heated Options To eliminate condensation and icing on the window
Electrical Specifications Operating Voltage: 24 VDC nominal (18-32 VDC)

Power Consumption:

  • Standby: Max. 90 mA (110 mA with heated window)
  • Alarm: Max. 130 mA (160 mA with heated window)

Cable Entries: 2 x ¾” – 14 NPT conduits or 2 x M25 x 1.5 mm ISO

Wiring: 12 – 22 AWG (2.5 mm 2 – 0.3mm2)

Electrical Input Protection: According to MIL-STD-1275B

Electromagnetic Compatibility: EMI/RFI protected to EN61326-3 and EN61000-6-3

Electrical Interface: The detector includes twelve (12) terminals with five (5) wiring options (factory set)

Outputs Relays:

  • Alarm, Fault, and Auxiliary
  • SPST volt-free contacts rated 5A at 30 VDC or 250 VAC

4-20 mA (stepped)

 

  • Sink (source option) configuration
  • Fault: 0 + 1 mA
  • Warning: 16 mA +/- 5%
  • BIT Fault: 2 mA +/- 10%
  • Alarm: 20 mA +/- 5%
  • Normal: 4 mA +/- 10%§ Resistance Loop: 100-600 ohms

HART Protocol: Optional HART communication on the 0-20 mA analog current (FSK) – used for maintenance, configuration changes and asset management, available in mA source output wiring options RS-485: RS-485 Modbus compatible communication link that can be used in computer control installations

Mechanical Specifications Materials/Enclosure Options: Heavy-duty copper free aluminum (less than 1%), red epoxy enamel finish (ATEX Approval only)

Stainless Steel 316L with electro polish finish (FM or ATEX Approval)

Mounting: Stainless Steel 316L with electro polish finish

Dimensions:

  • Detector: 4” x 4.6” x 6.18” (101.6 x 117 x 157 mm)

Weight

  • Aluminum: 2.8 lb. (1.3 Kg)
  • Stainless Steel 316L: 6.1 lb. (2.8 Kg)
  • Tilt Mount: 2.2 lb. (1.0 Kg)

Environmental Standards: Meets MIL-STD-810C for Humidity, Salt & Fog, Vibration, Mechanical Shock , High Temp, Low Temp

Water and Dust: IP66 and IP67 per En60529, NEMA 250 6P

Approvals Hazardous Area

  • ATEX & IECEx

    Ex II 2 GD
    Ex de IIB + H2 T5 (-55o to 75oC)
    Ex de IIB + H2 T4 (-55o to 85oC)
    Ex tD A21 IP66/X7 T 95oC
    Ex tD A21 IP66/X7 T 105oC

  • FM/CSA

    Class I Div. 1, Groups, B, C & D
    Class II/III Div. 1, Groups E, F & G

Performance

  • EN54-10 (LPCB)
  • FM-3260 (FM)

Reliability

  • IEC61508 – SIL-2 (TUV)
  • PDO Approval: Petroleum Development Oman Certificate of Registration
  • ISO 9001:2008: Registered Quality System
Accessories Fire Simulator: 20/20-310

Tilt Mount: 3600-01

Weather Protector: 777163

Air Shield: 777650

Mini Laptop Kit: 777820

USB RS-485 Harness Kit: 794079-5

Laser Pointer (Detector Area Coverage): 777166

pnGATE PB

Passerelle PROFINET vers PROFIBUS DP/PA (pnGate PB )

Intégration directe de segments  PROFIBUS DP et PA vers un système de contrôle PROFINET

  • Ré utilisez les “power confitioners” dans un projet de mises à jours de réseaux
  • Pas de segments PROFIBUS DP intermédiaire.
  • Préparez pour l’intégration standard et pour les outils d’Assets Managment.

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment coupler
  • Re-use of existing PROFIBUS segments without requiring modification
  • Support of PROFINET redundancy for increased reliability

Direct Connectivity to PROFIBUS Segments

  • Single access point to PROFIBUS DP and PROFIBUS PA segments from PROFINET networks
  • Acting as PROFINET Device, PROFIBUS PA and PROFIBUS DP Master
  • Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major PROFINET engineering tools such as TIA Portal, Step7 and PC WORXS
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM
Technical Details
Hardware Processor
Status LEDs (Gateway)Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9
PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update)
SF (system fault), BF (bus fault)
Interfaces and Connectors Ethernet

PROFIBUS PA

PROFIBUS DP-V0 / V1

2 * IEEE 802.3 100BASE-TX / 10BASE-T, embedded PROFINET switch for daisy chain topology
Connectors: RJ45
Protocol: PROFINET RT / IRT, Support of PROFINET redundancy protocols
RESTful API interface for device configuration
2 * PROFIBUS PA (MBP) segments,
Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC … 32 VDC,
current consumption 10 mA,
Connectors: 3-position screw connection, galvanically isolated
1 Segment with RS485 Physical Layer, Connector: 9-pin Sub-D socket
Physical Properties Dimensions (H x W x D)
Weight
Power SupplyOperating / Storage Temperature
Relative Humidity
Cooling
Coating
Mounting
Protection Class
100 mm x 35 mm x 115 mm
Approx. 0.25 kg
18 VDC … 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
No power supply to PROFIBUS PA segments through pnGate PB
-40 °C … +70 °C / -40 °C … +85 °C
(see detailed mounting description in user manual)
10 % … 95 %, non-condensing
Convection, no fan
Conformal coating based on ANSI / ISA-S71.04 G3
DIN rail 35 mm
IP20
Scope of Delivery
Hardware pnGate PB Gateway
Software GSDtoGSDML Converter, FDT CommDTM, PACTware, Drivers and Tools
Documentation On CD-ROM
Order Numbers
GCA-AN-024608 pnGate PB, PROFINET to PROFIBUS Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).
Additional Products and Services
GCA-AL-024602 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PROFIBUS PA devices).
GCA-AL-024604 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices).
GCA-AL-024605 pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices). For reversed mounting position on STAHL backplane
GCA-EL-024802 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PROFIBUS PA devices).
GCA-EL-024804 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices).

pnGate : Profinet to Profibus DP/PA