PROFIBUS CONNECTOR 90° Screw

The PROFIBUS connector 90° diagnostics LED is equipped with a proven and reliable screw terminal.

It is quickly mounted and has integrated, connectable terminating resistors.
For improved EMC compatibility, the housing of the plug is metalized.
Using the PROFIBUS connector diagnosis, a PROFIBUS network can be established in which the user can at any time check the state of the bus system at a glance.
The three built-in LEDs with the easily distinguished colors blue, green, and orange indicate the most important states of the PROFIBUS network at each station. The state of the terminating resistor (orange), whether bus activity is present (green), and whether the addressed participant is participating in the bus traffic (blue) are displayed.
In this way you can immediately recognize error states such as bus interrupts, missing or incorrectly connected terminating resistors, and malfunctioning or failed bus participants.
The PROFIBUS connector works in the extended ambient temperature range of -25 °C to +85 °C.

 

Exit on 2 versions : WITH PG and WITHOUT PG

  • 3 status LEDs to indicate “bus operation,” “participant is sending,” “terminating resistor inserted”
  • Metalized housing
  • No parts that can be lost
  • Integrated switchable terminating resistor
  • 90° cable outlet
  • Proven screw terminal
  • The PROFIBUS connectors are also available in packs of 10 or 50
  • The maximum ambient temperature for UL is +60 °C
General information
Order number 700-972-7BA12
Article name PROFIBUS connector, 90° screw terminal, diagnostics LED, without PG
Scope of delivery PROFIBUS connector, installation instructions
Dimensions (DxWxH) 64 x 40 x 17 mm
Weight Approx. 40 g
Cable outlet Vertical cable outlet, suitable for FastConnect stripping tool
PROFIBUS interface
Number 1
Transmission rate max. 12 Mbps
Connection SUB-D connector, 9-pin
Terminating resistor Resistor combination integrated and switchable using slide switch
PG connection socket No
PROFIBUS bus cable 60/75 °C copper cable up to 1.0 mm2
Connector
Connector type terminal strips
Number 4
Maximum outside diameter 8.0 mm
Status indicator 1 LED, 3-color
Voltage supply + 4.75 … + 5.25 V DC (must come from the device)
Current draw without modules (internal) Max. 35 mA
Ambient conditions
Ambient temperature -25 °C … +85 °C( The maximum ambient temperature for UL is +60 °C.)
Transport and storage temperature -25 °C … +85 °C
Relative air humidity 70 % at +25 °C
Pollution degree 2
Protection rating IP20
Certifications CE, UL
CE
RoHS Yes
REACH Yes

Product Reference

  • PROFIBUS connector, 90°, screw terminal connector, with diagnostics LED, without PG, incl. installation instructions : ATV-700-972-7BA12
  • PROFIBUS connector, 90°, screw terminal connector, with diagnostics LED, with PG, incl. installation instructions :       ATV-700-972-7BB12

répéteur PROFIBUS Compact

PROFIBUS compact répéteur

Le répéteur compact breveté PROFIBUS, est un répéteur PROFIBUS complet qui est polyvalent de par sa très petite taille. Il permet des taux de transfert de 9,6 kbps à 12 Mbps

 

  • Bonne alternative aux répéteurs PROFIBUS conventionnels
  • Pas d’espace supplémentaire requis dans l’armoire de commande
  • Peut être utilisé pour l’extension de bus ou comme ligne de dérivation
  • Augmente le nombre d’esclaves
  • Il étend votre réseaux PROFIBUS facilement
  • Peut aussi être utilisé sur le réseau MPI
  • Status LEDs
  • Pas d’alimentation 24V nécessaire
  • Alimentation 5v directement depuis le terminal PROFIBUS, ce qui le rend utile pour chaque esclave PROFIBUS

La transmission des signaux est regénérée par le répeteur et renvoyé (bit-reshaping and retransmission)  ce qui élimine bon nombre de fautes. Le “PROFIBUS Compact répéter” est une alternative  aux répéteurs conventionnels, pour bon nombre d’applications, par le cout et par la technicité utilisé. Il peut être utilisé pour l’extension d’un bus PROFIBUS ( jusqu’à 1 km avec 2* PROFIBUS  Compact Repeters, afin d’accroitre le nombre d’esclaves et d’étendre le système.

Utilisation possible sur le port MPI. Comme application bien spécifique, le “PROFIBUS Compact repetear” permets l’établissement de segments bien délimités. Pour cela, il peut être connecté sur le port PG, d’une connexion PROFIBUS

En raison de son design compact, aucun espace supplémentaire n’est nécessaire. Il peut être utilisé à la place de connecteur PROFIBUS “classic”. De plus, aucune alimentation n’est nécessaire. Un système de LEDs permet de voir l’état du réseau instantanément.

General information
Order number 700-972-0RB12
Article name PROFIBUS compact repeater
Scope of delivery PROFIBUS compact repeater, instructions
Dimensions (DxWxH) 64 x 40 x 17 mm
Weight Approx. 40 g
PROFIBUS interface
Number 1
Protocol PROFIBUS-DP
Transmission rate Max. 9.6 … 12 Mbps, autom. detection
Connection SUB-D connector, 9-pin
Cable outlet 90 °

Réference produit : ATV-700-972-0RB12

Memory card S7-1200/S7-1500

Memory Cards for S7-1200/S7-1500

S7 Memory Card S7-1200 S7-1500

The memory card for S7-1200*/S7-1500* controllers of Siemens AG.

Available with 4Mb / 12 Mb/ 24 Mb /256  Mb and 2 Gb

General information
Article name Memory Card, for S7-1200/S7-1500 series
Scope of delivery Memory Card
Storage volume depending on size selected
Application Options CPU 1200
CPU 1500

Reference Order :

  • 24Mb :    700-954-8LF03
  • 256 Mb : 700-954-8LL03
  • 2 Gb :     700-954-8LP03

mbGate PB

Passerelle : Réseaux Modbus TCP vers des réseaux PROFIBUS PA/DP

Avec la passerelle mbGate PB, nous pouvons désormais intégrer jusqu’à 2 segments PROFIBUS PA et 1 segment PROFIBUS DP à un système de controle Modbus TCP. La passerelle agit comme un serveur Modbus TCP  et un maitre PROFIBUS. Avec cette gateway, le cout de l’intégration est considérablement réduit.  Elle permet la paramétrisation et l’utilisation des outils standard de management.

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment couplers
  • Re-use of existing PROFIBUS segments without requiring modification

Direct Connectivity to PROFIBUS Segments

  • Single access point to PROFIBUS DP and PROFIBUS PA segments from Modbus TCP networks
  • Acting as Modbus TCP Server and PROFIBUS PA and PROFIBUS DP Master
  • Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major Modbus engineering tools such as Schneider Unity Pro or Siemens TIA Portal
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM

MODBUS/TCP Redundancy

  • Supports the use of two redundant PLCs and two redundant gateways
  • Easily enabled via licensing
  • Full control of redundant operation mode via engineering and PLC
Scope of Delivery
Hardware mbGate PB Gateway
Documentation On Website
Order Numbers
GCA-EN-024808 mbGate PB, Modbus TCP to PROFIBUS Gateway. Supports 2 PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).
Additional Products and Services
LRA-EN-024851 gatePlus HighAvailability, License for activating redundancy features in mbGate PB
LRL-DY-134501 dataFEED OPC Suite, Version 4.01 and higher, including all supported PLC protocols, support for OPC UA, access for any number of dataFEED OPC Tunnel Clients, for simultaneous access to a total of up to 100 OPC UA Servers, OPC Servers and OPC Tunnel Servers, and many more Functionalities such as Database and File Access, Data Exchange, Optimizer, Concentrator and Bridge
GCA-EL-024802 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 2 PA segments (up to 32 PA devices).
GCA-EL-024804 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 4 PA segments (up to 64 PA devices).
GCA-EN-024806 mbGate DP, Modbus TCP to PROFIBUS DP Gateway. Supports 1 PROFIBUS DP segment (RS485).

Video Channel : Retrouvez nous sur notre page channel YOUTUBE 

mbGate PA

Passerelle : MODBUS TCP vers Maitre PROFIBUS PA

Connexion simple d’esclaves PROFIBUS PA à un système de contrôle Modbus via mapping interne I/O

Avec la passerelle mbGate PA, il est possible d’intégrer jusqu’à 4 segments PROFIBUS PA dans des systèmes de contrôle Modbus TCP. Il agit en tant que serveur TCP Modbus et maître PROFIBUS PA. Grâce à nos passerelles, les coûts d’ingénierie peuvent être réduits, car elle réutilise les alimentations “Power conditionners”  existants dans des projets de mise à niveau. Il permet la configuration, le paramétrage et la gestion des esclaves de l’installation à l’aide d’outils industriels standards.

 

Elément clef pour une transition à la pointe de la technologie

  • Simple remplacement de segments coupler PROFIBUS DP/PA
  • Ré utilisation de segments existant PROFIBUS PA, sans modificiations

Connectivité directe aux segments PROFIBUS

  • Fonctionne comme serveur MODBUS et Maître PROFIBUS PA.
  • Connecte jusqu’à 4 segments PROFIBUS PA à MODBUS TCP

Configuration, Parametrisation et Gestion des esclaves en utilisant les outils standards industriels

  • Supporte la majorité des outils Modbus comme Schneider Unity Pro ou TIA Portal de Siemens
  • Incluant CommDTM et permetant l’utilisation des logiciels ” Frame applications”  FDT/DTM.
  • Parametrization des esclaves basés sur EDD, utilisant le logiciels Siemens Simatic PDM

Scope of Delivery
Hardware mbGate PA Gateway
Documentation On Website
Order Numbers
GCA-EL-024802 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 2 PA segments (up to 32 PA devices).
GCA-EL-024804 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 4 PA segments (up to 64 PA devices).
Additional Products and Services
LRL-DY-134501 dataFEED OPC Suite, Version 4.01 and higher, including all supported PLC protocols, support for OPC UA, access for any number of dataFEED OPC Tunnel Clients, for simultaneous access to a total of up to 100 OPC UA Servers, OPC Servers and OPC Tunnel Servers, and many more Functionalities such as Database and File Access, Data Exchange, Optimizer, Concentrator and Bridge
GCA-EN-024806 mbGate DP, Modbus TCP to PROFIBUS DP-Gateway. Support of 1 PROFIBUS DP segment (RS485).
GCA-EN-024808 mbGate PB, Modbus TCP to PROFIBUS Gateway. Supports 2 PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).

Retrouvez tous les téléchargements SOFTING  sur notre mirroir #1

Logiciel de configuration de réseaux Profibus DP

PROFIBUS DP Configurator

Configurateur de réseaux PROFIBUS DP : V 2.02.98

Outil de configuration de cartes Softing pour réseaux PROFIBUS DP. Il permet à l’utilisateur de configurer le réseau et de définirla carte comme maître. Le configurateur peut être utilisé dans de nombreuses applications pour configurer les cartes Softing comme Maître.
En fonction du cas d’utilisation, la fonctionnalité va de la définition de la structure du réseau avec ses appareils connectés et leurs paramètres, en passant par des tests interactifs en ligne d’entrées et de sorties spécifiques jusqu’à la définition de noms de points et de types de données pour toutes les données de processus disponibles au fur et à mesure de leur utilisation, comme pour être utilisé par un serveur OPC

Offline configuration
L’objectif d’une configuration hors ligne est de préparer un fichier de configuration binaire pour un contrôleur utilisant un maître Softing PROFIBUS DP. Le maître PROFIBUS DP peut être basé sur une carte d’interface PC ou implémenté en tant que solution intégrée utilisant les piles de protocoles et les cœurs IP de Softing.

Online configuration
La configuration en ligne utilise des cartes d’interface PROFIBUS installées sur le PC, sur lequel le configurateur PROFIBUS est utilisé.

Cela permet de rechercher sur le réseau, les périphériques connectés et de communiquer interactivement avec ces périphériques. Une configuration réseau peut être activée en utilisant la carte d’interface en tant que maître actif pour les périphériques connectés. Définition des noms de variable pour les variables

Pour chaque appareil configuré, il est possible d’affecter des variables de processus nommées à ses entrées et à sa sortie. Un type de données est également affecté à ces variables (par exemple, une valeur booléenne pour un seul bit ou un octet signé pour une entrée analogique). Ces variables peuvent ensuite être utilisées dans le configurateur PROFIBUS à des fins telles que la mise en service du réseau. Pour cela, les variables peuvent être lues et écrites dès l’activation de la configuration actuelle.
De plus, les variables nommées servent d’ “OPC Items”, si la configuration est utilisée pour un serveur OPC PROFIBUS de chez Softing.

Version gratuite disponible avec l’achat d’un carte Softing

 

=======================  Version End Of Life ===============

Référence : VCL-NN-017210

Sera délivré : Un logiciel et une clef USB

PBPro-ETH

Interface d’accès distante PROFIBUS pour une utilisation maitre ou esclave

PBpro ETH is a family of interfaces for remote access to one, two, three or four PROFIBUS segments via Ethernet for device parameterization, controller programming and data acquisition. On the PC the remote interface acts like a local PROFIBUS board.

PBpro-ETH

Large gamme d’applications

  • De-facto standard pour la parametrization des devices via  FDT/DTM
  • Connexion PROFIBUS pour des mesures et monitoring via PC ou serveurs
  • Interface externe PROFIBUS pour appareil PC ou systèmes embarquées
  • Intégration facile et rapide d’applications ‘OPC client’, comme des SCADA et systèmes MES via serveur OPC ( Option )

Protocole individuel pour chaque canal

  • Accès aux données “process” et paramètres au devices connecté comme maitre PROFIBUS ou Maitre classe 2 ( ou accès simultané avec système contrôle )
  • Echange de données avec controleur comme esclave PROFIBUS
  • Intégration dans syteème PROFIBUS FMS ou dans des application propriétaire via PROFIBUS FDL
  • Chaque canal agit comme interface PC PROFIBUS

Administration simple et intégration facile

  • Assignation d’un adresse IP  et configuration avec les outils ” search and configure” et interface web intégrée
  • Programmes d’exemple commentés, pour une utilisation facile et simple d’applications comme : PROFIBUS Application Programming Interface ( API)
  • Communication DTM gratuite pour PBPro ETH, supportant la parametrisation via les outils FDT
PBpro ETH
Single Channel
PBpro ETH
Dual Channel
PBpro ETH
Triple Channel
PBpro ETH
Quad Channel
Number of Channels 1 2 3 4
PROFIBUS Protocol 
DP-V0 Master All Channels All Channels All Channels
DP-V1 Master: Acyclic C2 Services All Channels All Channels All Channels
FMS All Channels All Channels All Channels
FDL All Channels All Channels All Channels
DP-V0 Slave Channel 2 Channel 2,3 Channel 2,3,4
Connector 9-pin D-Sub female, EIA-485 (RS-485), galvanically isolated
Transfer Rates 9.6; 19.2; 45.45; 93.75; 187.5; 500; 1500; 3000; 6000; 12000 Kbit/s
Host Interface
Ethernet 100BASE-TX/10BASE-T, 100 Mbit/s and 10 Mbit/s with automatic detection, RJ45 connector
Web Server For device status and configuration
Remote API Windows DLL for host computer
TCP/IP Socket Library Easily portable source code and programming samples for non-Windows computers
Miscellaneous
Mounting 35 mm DIN Rail
Dimensions (W x H x D) 47 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm
Power Supply 24 VDC (±20%) Typically 0.2A 24 VDC (±20%) Typically 0.3A 24 VDC (±20%) Typically 0.4A 24 VDC (±20%) Typically 0.5A
Temperature Range 0 °C … +55 °C (Operation); -20 °C … +70 °C (Storage); fanless convection cooling
Relative Humidity < 90%, Non-Condensing
Protection Class IP20
Available Drivers Windows 2000, Windows XP, Windows Vista, Windows 7, Windows 8, Windows Server 2003 R2, Windows Server 2008
DEL-NN-012311 PBpro ETH; 1 canal
DEL-NN-012312 PBpro ETH; 2 canaux
DEL-NN-012313 PBpro ETH; 3 canaux
DEL-NN-012314 PBpro ETH; 4 canaux

Ce que vous avez lors de la livraison

Hardware PROFIBUS Remote Interface
Software Windows Drivers, Sample Programs, PROFIdtm
Documentation User Guide

Produits complémentaires

OPC-PB PROFIBUS OPC Server for DP-V0 / DP-V1
DCF-DY-4100 OPC Server for S7 / S5
TRA-PB-TECH PROFIBUS Technology Training

PB-IF-03

PB-IF-03 : Carte Profibus, 1 canal, format ISA

PROFIboard une carte PC intéligente dans un réseau PROFIBUS DP. Elle est facile d’utilisation

Des applications tel que HMI, SCADA, interface ou controleur PC, peuvent accéder facilement aux réseaus PROFIBUS DP, grâce à cette carte.

.

  • Carte Profibus  : 1 canal format : ISA

  • Specific ; ISA spec

  • Température d’utilisation : [ 0°C / +55°C]

  • Carte rapide à mettre en Oeuvre

  • Support de protocoles variés

Unit

ISA PC-board, short AT format.

CPU Siemens SAB-C165 Microprocessor
Memory 512-Kbyte Flash, 512 Kbyte SRAM, 16 Kbyte dual port RAM
SUpported PC Interrupts 5,10,11,12,15
Profibus ASIC Siemens ASPC2 and SPC3
Physical Interface Galvanically isolated RS-485

Connector Type

1 x 9 pin Sub-d female
Connector Pinning EN 50 170, part 2 compliant
Hardware Configuration I/O address is set by switch on board; all other settings are software configurable
Power Supply +5 V (+-5%; typ. 700mA
Transfer Rate 9.6KKbit/ up to 12 Mbit/s
Humidity Rating <90% non-condensing
Temperature 0-55C Operating temperature

Reference :  PB-IF-03

Cette carte n’est plus en production. Veuillez vérifier sa disponibilité

pnGate PA

Passerelle PROFINET vers PROFIBUS PA (pnGate PA)

Intégration de segments PROFIBUS PA dans un sytème de contrôle PROFINET

  • Ré-utilsez vos power Conditioner dans une technologie plus avancée ?
  • Pas de segments PROFIBUS DP intermédiaires.
  • Préparé pour une intégration standard et pour les outils d’administration

Passerelle PROFINET : La clef essentiel pour une transition vers des technologies de pointe.

  • Passerelle PROFINET : Simple replacement des coupleurs PROFIBUS PA/DP
  • Ré-utilsation des segments PROFIBUS PA sans aucune modification
  • Support de la redondance PROFINET, afin d’accroitre la fiabilité.

Connexion directe aux segments PROFIBUS

  • Cette passerelle PROFINET/PROFIBUS PA est assimilé à un device PROFINET et un maître PROFIBUS PA
  • Supporte jusqu’à 4 segments PROFIBUS PA

Configuration, paramétrisation et outils d’administration aux Standard en vigeur pour cette passerelle PROFINET / PROFIBUS PA

  • Supporte  les outils PROFINET tels que: TIA Portal, Step7 et PC WORXS
  • Incluant  CommDTM et permettant l’utilisation d’applications FDT/DTM
  • Parametrisation EDD possible via Simantic PDM
Technical Details
Hardware Processor
Status LEDs (Gateway)Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9
PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update)
SF (system fault), BF (bus fault)
Interfaces and Connectors Ethernet

PROFIBUS PA

2 * IEEE 802.3 100BASE-TX / 10BASE-T, embedded PROFINET switch for daisy chain topology
Connectors: RJ45
Protocol: PROFINET RT / IRT, Support of PROFINET redundancy protocols
RESTful API interface for device configuration
Up to 4 PROFIBUS PA (MBP) segments (refer to the section “Order Numbers”),
Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC … 32 VDC,
current consumption 10 mA,
Connectors: 3-position screw connection, galvanically isolated
Physical Properties Dimensions (H x W x D)
Weight
Power SupplyOperating / Storage Temperature
Relative Humidity
Cooling
Coating
Mounting
Protection Class
100 mm x 35 mm x 105 mm
About 0.25 kg
18 VDC … 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
No power supply to PROFIBUS PA segments through pnGate PA
-40 °C … +70 °C / -40 °C … +85 °C
(see detailed mounting description in user manual)
10 % … 95 %, non-condensing
Convection, no fan
Conformal coating based on ANSI / ISA-S71.04 G3
DIN rail 35 mm
IP20
Scope of Delivery
Hardware pnGate PA Gateway
Software GSDtoGSDML Converter, FDT CommDTM, PACTware, Drivers and Tools
Documentation On CD-ROM
Order Numbers
GCA-AL-024602 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PAsegments (up to 32 PA devices).
GCA-AL-024604 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PAsegments (up to 64 PA devices).
GCA-AL-024605 pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices). For reversed mounting position on STAHL backplane.
Additional Products and Services
GCA-EL-024802 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices).
GCA-EL-024804 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices).

Si vous avez besoin de Firmware antérieur, veuillez nous contacter :  support@fr.atevatech.com

Les personnes intéressés par ce produit, peuvent aussi être intéressés par : 

  • pnGate PB : PROFINET to PROFIBUS Gateway. Supports up to 2 PROFIBUS PAsegments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).

pnGATE PB

Passerelle PROFINET vers PROFIBUS DP/PA (pnGate PB )

Intégration directe de segments  PROFIBUS DP et PA vers un système de contrôle PROFINET

  • Ré utilisez les “power confitioners” dans un projet de mises à jours de réseaux
  • Pas de segments PROFIBUS DP intermédiaire.
  • Préparez pour l’intégration standard et pour les outils d’Assets Managment.

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment coupler
  • Re-use of existing PROFIBUS segments without requiring modification
  • Support of PROFINET redundancy for increased reliability

Direct Connectivity to PROFIBUS Segments

  • Single access point to PROFIBUS DP and PROFIBUS PA segments from PROFINET networks
  • Acting as PROFINET Device, PROFIBUS PA and PROFIBUS DP Master
  • Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major PROFINET engineering tools such as TIA Portal, Step7 and PC WORXS
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM
Technical Details
Hardware Processor
Status LEDs (Gateway)Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9
PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update)
SF (system fault), BF (bus fault)
Interfaces and Connectors Ethernet

PROFIBUS PA

PROFIBUS DP-V0 / V1

2 * IEEE 802.3 100BASE-TX / 10BASE-T, embedded PROFINET switch for daisy chain topology
Connectors: RJ45
Protocol: PROFINET RT / IRT, Support of PROFINET redundancy protocols
RESTful API interface for device configuration
2 * PROFIBUS PA (MBP) segments,
Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC … 32 VDC,
current consumption 10 mA,
Connectors: 3-position screw connection, galvanically isolated
1 Segment with RS485 Physical Layer, Connector: 9-pin Sub-D socket
Physical Properties Dimensions (H x W x D)
Weight
Power SupplyOperating / Storage Temperature
Relative Humidity
Cooling
Coating
Mounting
Protection Class
100 mm x 35 mm x 115 mm
Approx. 0.25 kg
18 VDC … 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
No power supply to PROFIBUS PA segments through pnGate PB
-40 °C … +70 °C / -40 °C … +85 °C
(see detailed mounting description in user manual)
10 % … 95 %, non-condensing
Convection, no fan
Conformal coating based on ANSI / ISA-S71.04 G3
DIN rail 35 mm
IP20
Scope of Delivery
Hardware pnGate PB Gateway
Software GSDtoGSDML Converter, FDT CommDTM, PACTware, Drivers and Tools
Documentation On CD-ROM
Order Numbers
GCA-AN-024608 pnGate PB, PROFINET to PROFIBUS Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).
Additional Products and Services
GCA-AL-024602 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PROFIBUS PA devices).
GCA-AL-024604 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices).
GCA-AL-024605 pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices). For reversed mounting position on STAHL backplane
GCA-EL-024802 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PROFIBUS PA devices).
GCA-EL-024804 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices).

pnGate : Profinet to Profibus DP/PA